AQUASTREAM ULTIMATE

data sets is limited to 10. All selected values will be transmitted to the Aqua Com-
puter server by the Aqua Computer  background service approximately every 15
seconds, even after closing the aquasuite.
Notice regarding data security: All data contained in the configured export data
sets is transmitted to the Aqua Computer server with transport security. The server
stores the data set in volatile memory until a new data set is received or until 10
minutes have passed. Data received is not permanently stored, data is also not
correlated to IP addresses or other personal data. Data on the server may be ac-
cessed by anyone without restrictions, furthermore automatic data collection and
recording through third parties is possible. Use the data export feature for data
that you want to publish publicly and are allowed to do so only.

17.2.

17.2.

17.2.

17.2. Data access

Data access

Data access

Data access

Published data can be obtained from the Aqua Computer server in various for-
mats. Generally, the “access key” is required to access data.
In addition  to access through  any internet browser and importing data into the
aquasuite,  data is  also available  in  JSON format  and  compatible  to Circonus.
Furthermore, the server generates banner images in two different sizes from the
transmitted data, suitable to be included in forums signatures. The code required
for the Aqua Computer forums is provided for your convenience.

17.3.

17.3.

17.3.

17.3. Data import

Data import

Data import

Data import

To import a data set from the Aqua Computer server, the “access key” of the data
set is required. The access key can be found in the aquasuite on the computer
providing the data in the “Data access” section.
Create a new import entry by clicking the plus symbol in the upper right corner of
the “Data import” window. Enter the access key of the data set to be imported. Up
to 10 data sets (each containing up to 30 values) can be configured.
In order to verify that data is being imported, use the “Data quick view” feature in
the aquasuite. Navigate to “Data from Aqua Computer service”, then “aquasuite
web”. For each imported data set, you should find an entry with the name of the
data set containing the individual values. It may take a few seconds before import-
ed data is displayed. 

18.

18.

18.

18. Basic settings (aquasuite)

Basic settings (aquasuite)

Basic settings (aquasuite)

Basic settings (aquasuite)

Click the entry “Settings” below the headline “aquasuite” to access basic settings
for language, units and start-up of the software.

18.1.

18.1.

18.1.

18.1. Language

Language

Language

Language

Select a language from the drop down menu. After changing the language setting,
the software will have to be restarted. 

© 2016-2018

Aqua Computer GmbH & Co. KG

- 25 -

Gelliehäuser Str. 1, 37130 Gleichen

computer

aqua

Summary of Contents for aquastream ULTIMATE

Page 1: ...nd installation manual aquastream ULTIMATE aquasuite version 2018 Current as of October 2018 All information contained in this manual is subject to change without prior notice All rights reserved 2016...

Page 2: ...n 9 8 aquasuite software 9 8 1 Installation of the aquasuite software 9 8 2 Basic operation 10 8 3 Symbols in the headlines 10 9 Overview pages aquasuite 11 9 1 Desktop mode 11 9 2 Creating new overvi...

Page 3: ...ensor configuration 21 14 1 External flow sensor 21 14 2 Virtual flow sensor software extension Virtual Flow Sensor only 21 14 3 Offsets for temperature sensors 21 14 4 Software temperature sensors Ad...

Page 4: ...e to be observed at all times Read this manual thoroughly and entirely Save your data onto suitable media before working on your hardware The pump must not be placed under water The pump controller on...

Page 5: ...ump 5 5 5 5 Assembly instructions Assembly instructions Assembly instructions Assembly instructions Install connecting adapters not included in delivery to the aquastream ULTIMATE The adapters should...

Page 6: ...ou are having trouble to connect Pin assignment Pin 1 2 3 7 8 9 11 not connected Pin 4 5 6 10 12 GND Pin 13 14 15 12 V DC 6 3 6 3 6 3 6 3 Connector USB Connector USB Connector USB Connector USB This c...

Page 7: ...or the switching signal can be activated in case of an alarm condition for configuration see chapter 13 2 For example the aquabus speed signal cable in cluded in delivery can be used to connect this h...

Page 8: ...on of the aquastream ULTIMATE Operation of the aquastream ULTIMATE Operation of the aquastream ULTIMATE Operation of the aquastream ULTIMATE 7 1 7 1 7 1 7 1 Initial operation Initial operation Initial...

Page 9: ...isplay the aquasuite software should be closed on a connected PC Otherwise the aquasuite will overwrite and thereby cancel any settings made on the device itself 7 3 7 3 7 3 7 3 Configuration using US...

Page 10: ...icking the arrow symbol in the upper left corner List elements may be minimized or maximized for easier access by clicking the title bar The title bars may contain various symbols that will be explain...

Page 11: ...uasuite window for editing and the current desktop will be displayed as background for your convenience 9 2 9 2 9 2 9 2 Creating new overview pages and activating edit mode Creating new overview pages...

Page 12: ...vailable Headline only Compact display as a headline Text Displays the numerical value in a box with a headline Bar graph Displays numerical value as well as bar graph Chart Displays the value in chro...

Page 13: ...export individual elements select the element or elements perform a right click and select Export selected from the context menu For import right click a free spot of the page and select Import page...

Page 14: ...n the chart configura tion and select a data set to be displayed If no data sources are available you will have to configure the log settings as described in the chapter Log settings of this manual Se...

Page 15: ...Select the Data sources tab in the chart configuration and select a data set to be exported If no data sources are available you will have to configure the log settings as described in the chapter Log...

Page 16: ...eset speed preset If speed preset mode is selected you can manually set the desired rotation speed of the pump If the selected speed cannot be attained the pump controller will use the highest stable...

Page 17: ...om level for this axis a double click into the diagram will reset both axes Selecting an area on an axis will zoom this axis to this area selecting an area in the diagram will zoom both axes to this a...

Page 18: ...ent corresponding to the current temperature is scaled to the range between minimum and maximum fan power settings before being ap plied to the fan output The startup temperature will also be factored...

Page 19: ...tput range can be limited by setting Minimum power and Maximum power values correspondingly The check box Hold minimum power determines whether the fan will be switched off during a power setting of 0...

Page 20: ...t up but are not active presently are highlighted with a yel low background color Make sure only to use readings for alarm evaluation that are functional with your specific setup 13 4 13 4 13 4 13 4 S...

Page 21: ...y 10 Flow rates below 40 l h will not be displayed due to increasing imprecision of the calculation method for low flow rates Limitations Flow rate can not be calculated if a second pump is present in...

Page 22: ...r temperature sensor selection Water temperature sensor selection Select one of the available temperature sensors to be displayed as Water temper ature in the information pages on the pump display Thi...

Page 23: ...up port You may enter a Device description for easier identification this text will be displayed in the device list and in the data quick view 16 2 16 2 16 2 16 2 Factory defaults Factory defaults Fac...

Page 24: ...rmware update process the language of the pump menu will auto matically be set to the currently selected language in the aquasuite software To change the language of the pump menu first select the des...

Page 25: ...m the transmitted data suitable to be included in forums signatures The code required for the Aqua Computer forums is provided for your convenience 17 3 17 3 17 3 17 3 Data import Data import Data imp...

Page 26: ...lowing annual ver sion For software activation at least one device in the computer must contain a corresponding license If a valid license is detected for at least one device all de vices connected to...

Page 27: ...ess ing the middle key 3 Turn off the PC Press and hold the middle key and turn on the PC Release the key once pump data is displayed 19 2 19 2 19 2 19 2 Replacement parts Replacement parts Replacemen...

Page 28: ...his device has to be disposed of as electronic waste Please check your local regulations for disposal of electronic waste 20 4 20 4 20 4 20 4 Contact Aqua Computer Contact Aqua Computer Contact Aqua C...

Reviews: