AQUASTREAM ULTIMATE
11.
11.
11.
11. Pump configuration
Pump configuration
Pump configuration
Pump configuration
aquasuite: Select “Pump” from the device list below the “aquastream ULTIMATE”
entry. In the upper area, current pump data is displayed as plain text as well as in
a diagram. Select the desired mode of operation below the diagram.
Device menu: Select “Pump” from the menu list and confirm by pressing the mid-
dle key.
11.1.
11.1.
11.1.
11.1. Pump mode maximum power/automatic
Pump mode maximum power/automatic
Pump mode maximum power/automatic
Pump mode maximum power/automatic
If maximum power/automatic mode is selected, the pump will automatically oper-
ate at the highest attainable speed. The pump controller constantly monitors rotor
orientation, electrical current, power dissipation and supply voltage to calculate
optimum rotation speed. Using a standard water cooling setup, this speed will nor-
mally be around 4000 – 5000 rpm depending on the resistance of the system.
If “Manual speed settings” is selected, you can set the rotation speed of the pump
manually. If the selected speed cannot be attained, the pump controller will use
the highest stable rotation speed (below the set speed) just like in automatic mode.
11.2.
11.2.
11.2.
11.2. Pump mode
Pump mode
Pump mode
Pump mode speed preset
speed preset
speed preset
speed preset
If speed preset mode is selected, you can manually set the desired rotation speed
of the pump. If the selected speed cannot be attained, the pump controller will use
the highest stable rotation speed just like in automatic mode.
11.3.
11.3.
11.3.
11.3. Pump mode aquabus
Pump mode aquabus
Pump mode aquabus
Pump mode aquabus
This mode can be used to control pump speed by an aquaero 5/6 controller con-
nected to the pump via aquabus. If no data is transmitted to the pump via
aquabus, the pump controller will use the highest stable rotation speed just like in
automatic mode.
11.4.
11.4.
11.4.
11.4. Pump mode deaeration
Pump mode deaeration
Pump mode deaeration
Pump mode deaeration
While in deaeration mode, the pump will stop and run at top speed at regular in-
tervals to speed up the deaeration process. Deaeration mode is deactivated after
ten minutes.
11.5.
11.5.
11.5.
11.5. Pump mode
Pump mode
Pump mode
Pump mode temperature set point
temperature set point
temperature set point
temperature set point (Advanced Controller Package only)
(Advanced Controller Package only)
(Advanced Controller Package only)
(Advanced Controller Package only)
This mode can be used to automatically adjust pump speed depending on the cur-
rent temperature reading of one of the up to four available temperature sensors.
The desired target temperature can be configured, all other parameters should not
be changed for normal operation.
- 16 -
Aqua Computer GmbH & Co. KG
© 2016-2018