109
TDVOLT?
Read the active voltage value being displayed while a test is in process.
TDCURR?
Read the active current value being displayed while a test is in process.
TDAP?
Read the active peak current value being displayed while a test is in process.
TDP?
Read the active power value being displayed while a test is in process.
TDPF?
Read the active power factor value being displayed while a test is in process.
TDQ?
Read the active reactive current value being displayed while a test is in process.
TDCF?
Read the active crest factor value being displayed while a test is in process.
TDVA?
Read the active apparent power value being displayed while a test is in process.
TDTIMER?
Read the active timer meter value being displayed while a test is in process.
METER {4|3|2|1|0}
Selects the metered value that is displayed while a test is in process. 4 sets the
meter = power factor, 3 sets the meter = current, 2 sets the meter = power, 1 sets
the meter = peak current and 0 sets meter = frequency.
METER?
Read the selected meter value. Returns value of 0 – 4.
SDTRG
Triggers a one shot surge/drop in order to simulate loading or brown out
conditions.
STEPCYCLE?
Read the value of the current step cycle signal. When the step cycle has been
activated the query will return a value of 0 for continuous, 1 for Off or a range
from 0~9999 cycles.
Summary of Contents for 310XAC
Page 13: ...13 320XAC 340XAC...
Page 116: ...116 1 Test Complete OK WAI Wait for next command...