7000 Series 

AUTOMATED AC POWER SOURCES

For the following models:

7004, 7008, 7016, 7040

SAFETY

CHECKLIST

KEEP 

unqualified/unauthorized personnel away from test area

ARRANGE

 test stations in a safe and orderly manner

NEVER

 touch products or connections during a test

STOP

 the test first in the event of a problem

BE SURE

 to use the appropriate AWG for your input and output cabling

TURN OFF

 the output when making any connections to the load

       WARNING:

 THIS GUIDE WAS CREATED  

          FOR OPERATORS HAVING SOME FAMILIARITY 

          WITH AC POWER SOURCES AND HIGH 

VOLTAGE/HIGH CURRENT TESTING APPLICATIONS. 

AN AC POWER SOURCE PRODUCES VOLTAGES AND 

CURRENTS THAT CAN CAUSE HARMFUL OR FATAL 

ELECTRIC SHOCK. TO PREVENT ACCIDENTAL INJURY 

OR DEATH, THESE SAFETY PROCEDURES MUST BE 

STRICTLY OBSERVED WHEN HANDLING AND USING 

AN AC POWER SOURCE.

Via Acquanera, 29   

22100  Como

tel.  031.526.566 (r.a.)  fax  031.507.984

[email protected]   

www.calpower.it

Summary of Contents for APT 7000 Series

Page 1: ...input and output cabling TURN OFF the output when making any connections to the load WARNING THIS GUIDE WAS CREATED FOR OPERATORS HAVING SOME FAMILIARITY WITH AC POWER SOURCES AND HIGH VOLTAGE HIGH CU...

Page 2: ...ent s front panel is locked 9 UNIVERSAL AC OUTPUT SOCKET 300 VAC max voltage and 20 A max current Not available on the 7040 model 10 TEST RESET KEY Used to turn ON OFF output voltage or used to reset...

Page 3: ...r the 7008 7016 models To change the fuse unplug the power mains cord and turn the fuse cap counter clockwise to remove fuse The fuse compartment will be exposed Please replace the fuse with one of th...

Page 4: ...ound Output Terminal Earth ground chassis connection for line cord 10c Neutral Output Terminal Neutral screw terminal 10d Line Input Terminal Line input screw terminal for line cord 10e Ground Input T...

Page 5: ...ondition In MANUAL Mode the Rotary Knob on the front panel also becomes active It can be used to adjust voltage or frequency When the instrument is in an idle state it can also be used to edit the Hi...

Page 6: ...xt screen press the Edit soft key and use the up or down arrow soft keys to highlight the Connect parameter Now press the Edit soft key and in the next screen press the Change soft key to toggle the c...

Page 7: ...the Exit soft key two times to return to the Set screen 2 Program a current Hi Limit which represents the constant current you will provide to the load From the Set screen press the Edit soft key In t...

Page 8: ...sults Press the Exit soft key to move back to the set screen VIEWINGTESTRESULTS Figure 4 Results Screen For additional information about these and other key features of the 7000 Series please consult...