4.2
RS232 Set-up
The RS232 interface of the 44M04 mainframe is configured as follows:
Baud-rate:
9600 - 115200bps (selectable using the SYSTEM key)
Parity:
None
Data bit:
8 bits
Stop bit:
1 bit
Handshaking:
Hardware (RTS/CTS).
The RS232 Interface connector DB9 pin-out of the 44M04 is shown in Figure 15.
Figure 15: RS232 Connection to PC and DB9 Pin out
PIN
Abbreviation
Description
Pin1
DCD
Direct Carrier Detect
Pin2
TXD
Transmit Data
Pin3
RXD
Receive Data
Pin4
DTR
Data Terminal Ready
Pin5
GND
Ground
Pin6
DSR
Data Set Ready
Pin7
RTS
Request To Send
Pin8
CTS
Clear To Send
Pin9
RI