SECTION 7: CONNECTORS, APPLICATIONS & PROTECTION FEATURES
Entire Contents Copyright
2014 by Adaptive Power Systems, Inc. (APS) • All Rights Reserved • No reproduction without written authorization from APS.
42L Series Modular DC Load Operation Manual
Page 49 of 88
KEY# Description
18
SHORT key and LED Functions
1.
Short test function Enable/Disable Key: Press the “SHORT” key to enable the short test
function. The indicator LED will be lit. The LCD display shows “SHORT” on the top 5-digit
LCD display, shows “PRESS” on the middle 5-digit LCD display and shows START” on the
bottom 5-digit LCD display.
2.
Short test function parameter setting key: There are three parameters for the SHORT test
function. The parameters are: TIME, V-Hi and V-Lo. Press the “SHORT” key again to set
short test time when the SHORT test function is enabled. Press SHORT key again to
proceed to the next parameter and follow the sequence of TIME, V-Hi, V-Lo and Disable.
Press any another key to exit and save the SHORT settings.
The SHORT test parameter descriptions are as follows:
a.
TIME: Setting the short test time. The LCD display shows “SHORT”, “TIME” and CONT
(or initial setup value) on the left 5-digit LCD displays. The setting range is “CONTI”
which means continuous or 100ms to 10000ms in 100ms steps. Turn the rotary knob
clockwise to adjust this setting. The short test will have no time limitation when set to
“CONTI” until the “START/STOP” key is pressed to stop the short test.