![Apricus DeltaSol BS/4 Manual Download Page 7](http://html1.mh-extra.com/html/apricus/deltasol-bs-4/deltasol-bs-4_manual_2955800007.webp)
7
|
© 12128_Apricus_DeltaSol_BS4_V2.monen.ind
d
DeltaSol
®
BS/4
,EGEND
Symbol
Specification
x
Channel is available
x*
Channel is available if the corresponding option is activated.
s*
System-specific channel, only available if the corresponding option is activated
Adjustment Channels
Channel
Description
Factory setting
Page
Arr
x
System
1
20
DT O
x
Switch-on temperature difference
8.0 K [16.0 °Ra]
20
DT F
x
Switch-off temperature difference
1.0 K [2.0 °Ra]
20
DT S
x
Nominal temperature difference
10.0 K [20.0 °Ra]
20
RIS
x
Rise control R1
2 K [4 °Ra]
20
nMN
x
Minimum pump speed
100 %
20
S MX
x
Maximum store temperature
85 °C [186 °F]
21
OSEM
x
Option store emergency shutdown
OFF
21
EM
x
Emergency temperature collector
130 °C [270 °F]
21
Emergency temperature collector if ODB is activated:
95 °C [200 °F]
21
OCC
x
Option collector cooling
OFF
22
CMX
x*
Maximum collector temperature
110 °C [230 °F]
22
OSYC
x
Option system cooling
OFF
22
DTCO
x*
Cooling switch-on temperature difference
20.0 K [40.0 °Ra]
22
DTCF
x*
Cooling switch-off temperature difference
15.0 K [30.0 °Ra]
22
OSTC
x
Option store cooling
OFF
23
OHOL
x*
Option holiday cooling
OFF
23
THOL
x*
Holiday cooling temperature
40 °C [110 °F]
23
OCN
x
Option minimum limitation
OFF
23
CMN
x*
Minimum collector temperature
10 °C [50 °F]
23
OCF
x
Option antifreeze
ON
23
CFR
x*
Antifreeze temperature
4.0 °C [40.0 °F]
23
O TC
x
Option tube collector
OFF
24
TCST
x*
OTC starting time
07:00
24
TCEN
x*
OTC ending time
19:00
24
TCRU
x*
OTC runtime
30 s
24
TCIN
x*
OTC standstill interval
30 min
24
OHQM
x
Option heat quantity measurement
OFF
24
FMAX
x*
Maximum flow
6.0 l
24
MEDT
x*
Antifreeze type
1
24
MED%
x*
Antifreeze concentration (only if MEDT = propylene or ethylene)
45 %
24
ODB
x
Drainback option
OFF
25
tDTO
x*
ODB switch-on condition - time period
60 s
25
tFLL
x*
ODB filling time
5.0 min
25
tSTB
x*
ODB stabilisation time
2.0 min
25
OBST
s*
Option booster function
OFF
25
MAN1
x
Manual operation R1
Auto
26
MAN2
x
Manual operation R2
Auto
26
ADA1
x
HE pump control
OFF
26
LANG
x
Language
En
26
UNIT
x
Temperature unit
°C
26
RESE
x
Reset - back to factory settings
26
W004####
Version number