15
|
© 12128_Apricus_DeltaSol_BS4_V2.monen.ind
d
DeltaSol
®
BS/4
The system screen (active system layout) shows the system
selected on the controller. It consists of several system
component symbols, which are – depending on the current
status of the system – either flashing, permanently shown
or hidden.
3-way valve
The flow direction or the
actual switching position is
shown
System screen
system screen
green:
everything OK
red/green flashing initialisation phase
manual operation
red flashing:
sensor fault
(sensor symbol is flashing quickly)
&LASHINGCODES
LED flashing codes
System screen flashing codes
Pump
Store
with heat exchanger
Afterheating
with burner symbol
Temperature sensor
Collector
with collector sensor
collector sensor
collector
valve
store
store heat exchanger
store sensor (top)
store sensor
(base)
afterheating pump
solar pump
booster pump
afterheating with
burner symbol
heat exchanger
(heat dump)
s
Pumps are flashing when the corresponding relay is swit-
ched on
s
Sensor symbols are flashing if the corresponding sensor
display channel is selected
s
Sensors are flashing quickly in the case of a sensor fault
s
Burner symbol is flashing if the afterheating is active