© 12128_Apricus_DeltaSol_BS4_V2.monen.ind
d
|
16
DeltaSol
®
BS/4
3. Commissioning
Î
Establish the power supply
During a short initialisation phase, the operating control
lamp flashes red and green.
When the controller is commissioned for the first time
or after a reset, it will run a commissioning menu. The
commissioning menu leads the user through the most
important adjustment channels needed for operating the
system.
/PERATINGTHECOMMISSIONINGMENU
Î
Enter the channel by pressing button 3
The
symbol flashes.
Î
Adjust the value by pressing buttons 1 and 2
Î
Save the adjustment by pressing button 3 again
The
symbol stops flashing.
Î
Press button 1 or 2 to switch to the next or previous
channel
1
2
3
(OK)
The three pushbuttons of the BS/4 controller
The commissioning menu consists of the following 6
channels:
1. Language
Î
Adjust the desired menu language in this channel
s
dE : German
s
En : English
s
Fr : French
,!.'
Language selection
Selection: dE, En, Fr
Factory setting: En
5NIT
Î
Adjust the unit in which temperatures and temperature
differences shall be displayed
5.)4
Temperature unit selection
Selection: °F, °C
Factory setting: °C
3. Time
Î
Adjust the current time for the real time clock
The hours and minutes have to be adjusted separately, first
the hours, then the minutes.
4)-%
Real time adjustment