![Apricus DeltaSol BS/4 Manual Download Page 14](http://html1.mh-extra.com/html/apricus/deltasol-bs-4/deltasol-bs-4_manual_2955800014.webp)
© 12128_Apricus_DeltaSol_BS4_V2.monen.ind
d
|
14
DeltaSol
®
BS/4
The system monitoring display consists of three blocks:
channel display,
tool bar
and
system screen
(active
system layout).
The
channel display
consists of 2 lines. The upper line
is an alpha-numeric 16-segment display (text display) for
displaying channel names and menu items. In the lower
7-segment display, the channel values and the adjustment
parameters are displayed.
Temperatures are either indicated in °F or °C, whereas tem-
perature differences are indicated in K or °Ra respectively.
The additional symbols of the
tool bar
indicate the current
system status.
channel display
tool bar
2. Operation and function
2.1 Push buttons
The controller is operated via three push buttons below
the display.
"UTTON
is used for scrolling forward through the indica-
tion menu or to increase the adjustment values.
"UTTON
is
used for scrolling backward and reducing values.
"UTTON
is used for selecting channels and confirming adjustments.
During normal operation, only the display channels are
shown.
Î
Scroll through the display channels by pressing buttons
1 and 2
!CCESSINGTHEADJUSTMENTCHANNELS
Î
Scroll down in the display menu and press button 1
for approx. 2 seconds after you have reached the last
display item.
When an
adjustment value
is shown on the display,
is indicated to the right of the channel name.
Î
Press button 3 in order to access the adjustment mode
starts flashing.
Î
Adjust the value using buttons 1 and 2
Î
Briefly press button 3,
permanently appears,the
adjusted value will be saved.
2.2 System-Monitoring-Display
system monitoring display
1
3
2
backward (-)
forward (+)
OK
(selection / adjustment mode)
operating control lamp
Status
standard flashing
relay 1 active
relay 2 active
maximum store temperature exceeded
store emergency shutdown active
+
collector emergency shutdown active
collector cooling active
system cooling active
store cooling active
+
holiday cooling function activated
holiday cooling function active
+
collector minimum limitation active
antifreeze function activated
antifreeze function active
manual operation relay 1 ON
+
manual operation relay 2 ON
+
manual operation relay 1 / 2 OFF
sensor defective