7. Troubleshooting
F
AULT
/
S
YMPTOM
No Power light on the front panel of Easytrak Nexus
P
OSSIBLE
C
AUSES
The Power supply.
Is there power to the socket? The Power supply
is not plugged into Alpha, or the Wall socket, or not switched on.
F
AULT
/
S
YMPTOM
No Signal return at any range
P
OSSIBLE
C
AUSES
Incorrect Channel.
Check Beacon editor
Beacon TX power.
This may be due to a discharged battery, fouled
transducer, or beacon fault. Try with a known working beacon.
Obstruction.
The beacon’s signal may be blocked by submerged
parts of the vessel, seabed objects – manmade or natural.
Deck Cable.
Check that the deck cable or connectors have not been
damaged. Look for cuts, splits or abrasions. Check there is no
corrosion on the connector pins.
Damaged responder cable
. Check the pulse from Nexus is present
at the Responder end of the cable (approx 12VDC pulse on load).
Confirmation
. Temporarily locate the transducer and a suitable
beacon on-deck. Try interrogating the beacon. Is the transducer
transmitting (clicking)? Is the beacon transmitting (clicking)? No, try
another transducer / beacon. Is Easytrak Nexus receiving the
beacon’s transmission? If there is still no response the transducer is
suspect.
F
AULT
/
S
YMPTOM
Incorrect Range
P
OSSIBLE
C
AUSES
Incorrect Velocity of Sound.
Enter correct value.
Turn around delay.
Is the turn around delay set correctly in the
beacon? Correct turn around delay.
Another beacon in the water set to the same channel.
Another sonar system transmitting at the beacon’s reply frequency.
F
AULT
/
S
YMPTOM
Short range
P
OSSIBLE
C
AUSE
Excessive range for conditions.
Range is dependent on local
conditions such as in-band noise from man-made or marine sources.
If possible reduce noise or work at a shorter range.
Beacon reply insensitivity.
This may be due to a fouled
transducer, or beacon fault. Clean beacon transducer with fresh
water. Try using another beacon.
Transducer reply insensitivity.
Check that the transducer is not
damaged or fouled. Clean transducer with fresh water.
Obstruction.
The beacon’s signal may be blocked by submerged
Summary of Contents for Easytrak Nexus Lite 2683
Page 1: ...Easytrak Nexus Lite 2695 Series Operation Manual ...
Page 13: ...2695 Series Operation Manual EZT 2695 8000 1 Page 13 of 124 ...
Page 85: ...2695 Series Operation Manual EZT 2695 8000 1 Page 85 of 124 Summary Report ...
Page 86: ...2695 Series Operation Manual EZT 2695 8000 1 Page 86 of 124 Complete Listing of Dataset ...
Page 88: ...2695 Series Operation Manual EZT 2695 8000 1 Page 88 of 124 ...
Page 89: ...2695 Series Operation Manual EZT 2695 8000 1 Page 89 of 124 ...