2695 Series Operation Manual
EZT-2695-8000/1
Page
50
of
124
Release
The release tab enables control of Applied Acoustics 5xx or 15xx release beacons.
General Operation
The release tab, will not be visible until the ‘Target Type’ is selected as a release type in the
‘General’ tab.
5xx Release Operation
Release ID
The 5xx release beacon will have an ID (0 – 15), determined by the release beacon switch
settings. To communicate with the beacon, the ID must be set from the ‘Release ID’ drop down
selection box.
Release Status Flags
This area displays the operational status of the release beacon. The ‘Read Status’ button may be
pressed to interrogate the release beacon and obtain the current operational status.
Please refer to the release beacon manual for a detailed description of each of the status flags.
Release Actions
A number of actions may be performed with a release beacon.
•
Arm – A release beacon must be armed prior to release. Once the beacon is armed (as
indicated by the status flags) the ‘Release’ button will become active
•
Release – Once armed, a release operation may be performed. The user will be prompted
to confirm that a release operation is required prior to actioning the release
•
Reset – This will reset the release status flags to their default conditions. Note however that
if any fault condition remains this will be indicated in the status flags.
Release functionality is an add on feature that must be enabled.
Summary of Contents for Easytrak Nexus Lite 2683
Page 1: ...Easytrak Nexus Lite 2695 Series Operation Manual ...
Page 13: ...2695 Series Operation Manual EZT 2695 8000 1 Page 13 of 124 ...
Page 85: ...2695 Series Operation Manual EZT 2695 8000 1 Page 85 of 124 Summary Report ...
Page 86: ...2695 Series Operation Manual EZT 2695 8000 1 Page 86 of 124 Complete Listing of Dataset ...
Page 88: ...2695 Series Operation Manual EZT 2695 8000 1 Page 88 of 124 ...
Page 89: ...2695 Series Operation Manual EZT 2695 8000 1 Page 89 of 124 ...