19.2.2 Cycle Count Reset
Press MENU key at teaching mode, and select “Soldering
System Settings”.
Then, select “Cycle Count Reset” and press ENTER .
Press CLEAR key to reset the number.
19.3 One Touch Feed Length
Solder wire can be fed to the top of solder tube.
It is useful function, when solder wire is replaced.
*Initial value: “0”
(Setting range 0~900mm)
Press MENU key at teaching mode, and select “Soldering
System Settings”.
Then, select “One Touch Feed Length” and press ENTER .
Enter the same length of the solder tube.
The solder wire is fed in 20mm shorter than the entered length
to avoid solder wire overrun.
By pressing 9 on teaching pendant, the solder wire can be
fed.
Soldering System Settings
IO Function Assignment
Iron Shot Counter Disable
Cycle Count Enable
Cycle Count Reset 0
One Touch Feed Length 0mm
APN05 Alarm Display Disable
Type of Restart Program End
Type of Error Reset START BUTTON
Feeder Calibration 100%
Manual Feed Speed 50mm/s
Soldering System Settings
Enter a number
Cycle Count Reset 0
Soldering System Settings
IO Function Assignment
Iron Shot Counter Disable
Cycle Count Disable
One Touch Feed Length 0mm
APN05 Alarm Display Disable
Type of Restart Program End
Type of Error Reset START BUTTON
Feeder Calibration 100%
Manual Feed Speed 50mm/s
Soldering System Settings
Enter a number
One Touch Feed Length 650mm