Page 43 of 60
Switch Run Mode Program1
Stopping Start Enable
Top of Cycle
Please change an Iron Cartridge.
IRON SHOT COUNTER
102 / 10000
19.1.1 Iron Shot Counter (Display at the operation mode)
Iron Shot Counter is displayed in External Run Mode or Switch Run Mode as follows:
During the operation mode,
the iron shot counter is updated in every one shot.
When the present value of the counter reaches the maximum iron shot counter point, the message
on teaching pendant appears and a buzzer sounds. (The robot operation enables after reaching
set value.)
To turn off the buzzer, reset the counter current value while the
machine is stopping.
Because iron shot counter checking is done at the time of the
program end, the current value becomes bigger value than
maximum iron shot number.
19.1.2 Iron Shot Counter Reset
How to reset Iron Shot Counter
Press MENU key at teaching mode, and select “Soldering
System Settings”.
Then, select “Iron Shot Counter Reset” and press ENTER .
Press CLEAR key to clear the number.
It should be done everytime after replacing to new iron
cartridge.
Switch Run Mode Program1
Stopping Start Enable
Top of Cycle
IRON SHOT COUNTER
102 / 10000
Iron Shot Counter Present value
Iron Shot Counter Setting value
This message is displayed.
Soldering System Settings
IO Function Assignment
Iron Shot Counter Disable
Iron Shot Counter SV 10000
Iron Shot Counter Reset 102
Cycle Count Disable
One Touch Feed Length 0mm
APN05 Alarm Display Disable
Type of Restart Program End
Type of Error Reset START BUTTON
Feeder Calibration 100%
Manual Feed Speed 50mm/s
Soldering System Settings
Enter a number
Counter Reset 0