Switch Run Mode Program1
Stopping Start Enable
Top of Cycle
Cycle Count
2
IRON SHOT COUNTER
102 / 10000
19.2 Cycle Count
The number of program cycle can be counted.
1 cycle is 1 count. ( It is not counted during the continuous operation mode.)
*Factory setting: “Enable”.
Press MENU key at teaching mode, and select “Soldering
System Settings”.
Then, select “Cycle Count” and press ENTER .
Select “Enable”.
19.2.1 Cycle Count (Display at the operation mode)
Iron Shot Counter is displayed in External Run Mode or Switch Run Mode as follows:
During External operation mode or Switch run mode,
it is counted at the time running program ends 1 cycle,
then it is displayed on teaching pendant.
The cycle count value is not updated during robot running.
Indication is reflected after the end of the program.
*It is not counted during continuous operation mode.
The maximum setting number of cycle count is 99999, if it’s 10000cysles, it becomes 0.
(This is repeated.)
Soldering System Settings
IO Function Assignment
Iron Shot Counter Disable
Cycle Count Disable
One Touch Feed Length 0mm
APN05 Alarm Display Disable
Type of Restart Program End
Type of Error Reset START BUTTON
Feeder Calibration 100%
Manual Feed Speed 50mm/s
Iron Shot Counter
Disable
Enable
Cycle count value