EN
Use and Maintenance manual J series ING Rev E;
Page 103 of 108
Setting the baking steps for each automatic programme (Maximum 200).
Enter the
“Hidden parameters” and select the desired data to set th number of steps for each
programme.
The icon showing the ongoing step is displayed only when the instrument is in Start mode and it
is running an automatic programme.
In the various baking steps different values can be set for:
•
Temperature
•
Baking time
•
Steam time
•
Fan speed
•
Steam exhaust valve Open or Closed
If the phases number is set to “0” the phases table doesn’t appear in the main screenful.
If the phases number is set to
“5” the phases table appears on a single screenful,
If the phases number is set to
“10” the phases table appears on two screenful.
IMPORTANT :
It is necessary that the phase table (both 5 and 10) be fully compiled, otherwise the program will not be stored.