10
FBL2360 Brushless DC Motor Controller Datasheet
Version 1.3 August 29, 2019
TABLE 6.
Connector
Pin
Power
Dout
Com
Pulse
Ana
Dinput
Enc
Hall (4)
Default
Config
1
GND
14
5VOut
2
RS TxD
RS232Tx
15
RC1
ANA1
DIN1/
STO1 (2)
Hall1A
RCRadio1 (3)
3
RS RxD
RS232Rx
16
RC2
ANA2
DIN2/
STO2 (2)
Hall1B
RCRadio2 (3)
4
RC3
ANA3
DIN3
Hall1C
AnaCmd1 (1)
17
RC4 ANA4/EXC
DIN4
Hall2A
AnaCmd2 (1)
5
GND
18
DOUT1
Motor Brake 1
6
DOUT2
Motor Brake 2
19
DOUT3
Contactor
7
DOUT4
Unused
20
CANH
Unused
8
CANL
Unused
21
RC5
ANA5
DIN5
ENC2A Hall2B
Unused
9
ASIN1
DIN9
Unused
22
RC6
ANA6
DIN6
ENC2B Hall2C
Unused
10
ACOS1
DIN10
Unused
23
485 +
RS485 +
11
485 –
RS485 –
24
RC7
ANA7/
ASIN2
DIN7
ENC1A
Unused
12
RC8
ANA8/
ACOS2
DIN8
ENC1B
Unused
25
5VOut
13
GND
Note 1: Analog command is disabled in factory default configuration.
Note 2: STO functionality only available in T versions. See STO section for details.
Note 3: Pulse input enable by default on firmware version prior to v2.0
Note 4: Hall inputs are activated in DB25 connector in firmware v2.0 or later and only if Molex input is
configured as SSI Input. In that case user has to install 1K pull up resistor between each hall signal and 5VOut.
Default I/O Configuration
While the controller can be configured so that practically any Digital, Analog and RC pin
can be used for any purpose, the controller’s factory default configuration provides an
assignment that is suitable for most applications. The figure below shows how to wire the
controller to two analog potentiometers, an RC radio, and the RS232 port. It also shows
10
FBL2360_1691-21588-0001-D-0720