FBL2360 Brushless DC Motor Controller Datasheet
17
Electrical Specifications
Scripting
TABLE 11.
Parameter
Measure Point
Min
Typ
Max
Units
Scripting Flash Memory
Internal
32K
Bytes
Max Basic Language programs
Internal
2000
3000
Lines
Integer Variables
Internal
4096
Words (1)
Boolean Variables
Internal
8192
Symbols
Execution Speed
Internal
50 000
100 000
Lines/s
Note 1: 32-bit words
Thermal Specifications
TABLE 12.
Parameter
Measure Point
Min
Typ
Max
Units
Case Temperature
Case
-40
85 (1)
o
C
Thermal Protection range
Case
80
90 (2)
o
C
Power Dissipation
Case
70
Watts
Thermal resistance
Power MOSFETs to case
0.6
o
C/W
Humidity
Case
95
%
Ambient temperature
Ambient
55
o
C
Pollution Degree
-
Fast fuse to install (3)
FBL2360 (4)
40
2 x 40
Amps
FBL2360S (4)
2 x 40
Amps
Overload motor protection
-
Check note 5
Note 1: Thermal protection will protect the controller power
Note 2: Max allowed power out starts lowering at minimum of range, down to 0 at max of range
Note 3: There are two power terminal tabs. Fuse should be installed in both of them for safety.
Note 4: In dual channel controller, for operating only one channel install 40A fuse and for operating both
channels 2 x 40A fuse should be installed. Power source must be capable to blow the fuse instantly in
case of short circuit
Note 5: Current limiting mechanism available through firmware. External overload motor protection can
be used if required (provided by user)
17