Technical Manual | 808AH V1.2
22
TROUBLESHOOTING | Anyload Weigh & Measure Inc. @ www.anyload.com
5.2
E
RROR
C
ODES
Error
Description
Action
Communication baud rate failure
Check wirings for proper connection
Incoming string protocol failure
Check Indicator to be in continuous mode
Wireless communication failure
Check installed RF module
Factory setting failure
Perform factory reset
Memory checksum failure
Perform factory reset
Data communication failure
Check communication setting, wiring and indicator
5.3
D
ISPLAY
M
ESSAGES
Message
Description
Reason
Shows dashes or blanks display
Data communication failure
OCAP for over capacity on scale
Set by indicator by sending a special character
OVER for out of range weight setting
Set by remote display in setup menu
LEARN for auto learn baud and protocol
Auto learn mode to detect baud rate and protocol
SAVED for saving setup information
Setup data stored in flash memory
TEST for running a display test
Display tests segments and brightness
5.4
P
USH
B
UTTONS
Button
Description
Function
TEST
TEST
Tests brightness levels
Tests display segments
Tests annunciators
Performs a full display test
RESET
RESET
Runs a cycle test
Loads startup values
Shows version number
Performs a hardware reset
LOCK
LOCK
Loads protocol and baud from stored values
Avoids unnecessary delays at start up
Locks if learn is successful at start up
Locks to latest successful configuration