![Anyload 808 Series Technical Manual Download Page 11](http://html.mh-extra.com/html/anyload/808-series/808-series_technical-manual_2948870011.webp)
Technical Manual | 808AH V1.2
Anyload Weigh & Measure Inc. @ www.anyload.com | WIRING
9
3.2
E
LECTRICAL
P
OWER
W
IRING
The 808AH remote displays are pre-wired AC devices with regional power cable cord installed via
strain reliefs. The proper grounding is provided as default. The standard 808AH remote displays do
not have any ON / OFF power switch. Therefore, before any installations, make sure all power
sources are disconnected.
It is required to use a ground fault circuit interrupter to supply AC lines to the device at the site to
avoid any risk or hazard. For the applications requiring custom wiring, all safety precautions and
proper grounding must be considered. This table is based on color codes commonly used in North
America. For other regions, the local codes must be obtained and observed.
Power Cord
Power Supply
Wire
Color
Color
Wire
Neutral
White
Blue
N
Live
Black
Brown
L
Green
-
Item
AC Power Supply
Description
1
Input
AC 100-240V~ 1.2A 50-60HZ
2
Output
DC 12V 5A 60W
3
Enclosure
Encapsulated IP67
4
Protection
Short circuit, Over load, Over voltage
5
Approval
Class II UL / CUL approved, CB CE
Symbol
Description
WARNING!
Make sure the power source is disconnected before any installation
Make sure the site has proper grounding
CAUTION!
Any unauthorized change or alteration in default wiring may void warranty
Any installation and wiring must be handled by authorized personnel
NOTICE!
Refer to the local electrical code for the wiring color codes
Refer to the installation section for instructions to how to access to the wiring terminals