Technical Manual | 808AH V1.2
20
CONFIGURATION | Anyload Weigh & Measure Inc. @ www.anyload.com
4.8
F5
A
UXILIARY
S
ETTING
Function
Value
Setting
Description
F5.0
Switch Function
0
1
2
Disabled
Momentary
Latch
If set to Disable, both SW1 and SW2 are disabled as default.
If set to Momentary, both SW1 and SW2 are active as push buttons.
If set to Latch, both SW1 and SW2 are active in latched mode.
F5.1
Relay Function
0
1
Disabled
Enabled
If set to1, relay function is active.
It operates based on SW1 current state.
It is disabled as default.
Refer to wiring chapter and relay section of this technical manual.
F5.2
Traffic Light
Function
0
Disabled
Not available with this version.
Availability of this function is based on firmware release.
F5.3
Switch 1
Message
0
1
2
3
4
Disabled
It shows predefined messages on display if SW1 is not disabled.
Refer to the wiring chapter and switch section of the manual.
Default messages are as follows:
CLOSED
DRIVE
START
ENTER
F5.4
Switch 2
Message
0
1
2
3
4
Disabled
It shows predefined messages on display if SW2 is not disabled.
Refer to the wiring chapter and switch section of the manual.
Default messages are as follows:
OPEN
STOP
HALT
QUIT