2 - 50
Chapter 2 Operation
Error Message
Description
DIST REQUIRES
F1 < F2
Valid distance to fault plots require a non-
zero frequency span.
DIST REQUIRES
CAL
Distance-to-fault measurements do not pro-
vide usable data with CAL OFF.
NO STORED
SWEEP AT THIS
LOCATION
Attempting to recall a display from a loca-
tion that has not been previously written to.
That is, the location does not contain stored
sweep.
USE OPTIONS
MENU TO
SELECT A
PRINTER
Attempting to print a display with no printer
selected. Select a printer, then retry.
DISTANCE AND
CABLE
INSERTION LOSS
MODE ARE
INCOMPATIBLE
DTF measurements only display RL or
SWR versus distance.
CANNOT ZERO
NO DETECTOR
INSTALLED
Attempting to perform a Power Monitor
zero adjust function with no RF detector
connected to the Site Master.
CANNOT ZERO
INPUT SIGNAL
TOO HIGH
Attempting to perform a Power Monitor
zero adjust function with an input of greater
than –20 dBm.
POWER MONITOR
OPTION NOT
INSTALLED
Attempting to enter Power Monitor mode
with no option 5 installed.
Table 2-3.
Range Error Messages (2 of 2)
Summary of Contents for Site Master S330A
Page 3: ......
Page 15: ...This page is intentionally blank 1 7 Chapter 1 General Information...
Page 23: ...2 7 Chapter 2 Operation Figure 2 3 Site Master Menu Structure...
Page 54: ...2 38 Chapter 2 Operation Figure 2 10 Maximum Distance and Resolution vs Frequency Span...
Page 83: ...3 14 Chapter 3 Screen Capture Program NOTES...
Page 85: ...Color Cover P N 00986 00018...