Distance
Menu
(DIST)
Provides for setting Distance to Fault parameters. Se-
lected distance values may be changed using the key-
pad or Up/Down Arrow key. Entry can be in feet or
meters, depending on the setting of the B5 soft key in
the Option Sub-Menu (page 2-20).
Choosing
DIST
causes the soft keys, below, to be
displayed and the corresponding values to be shown
in the message area.
q
D1
— Opens the start distance (D1) parameter for
data entry. This is the start value for the distance
range. Press
ENTER
when data entry is complete.
q
D2
— Opens the end distance (D2) parameter for
data entry. This is the end value for the distance
range. Press
ENTER
when data entry is complete.
q
MKRS
— Selects the Markers Menu, described
on page 2-10.
q
DTF AID
— Provides interactive help to optimize
DTF set up parameters. User is prompted for sys-
tem parameter values of maximum distance, cen-
ter frequency, and propagation velocity.
Frequency parameters are then calculated to opti-
mize both range and resolution.
q
MORE
— Selects the Distance Sub-Menu, de-
scribed on page 2-14.