A-86
37XXXC OM
G
ALPHABETICAL LISTING
1. TEST PORT 1 POWER SHOULD BE APPROXIMATELY=
AUT(x dB compression
spec) - AUT(gain)
- 15 dB
2. PORT 2 INPUT POWER SHOULD BE LESS THAN 0 dBm
(UNLESS OPTION 6 IS INSTALLED).
3. NOMINAL OFFSET = APPROXIMATE GAIN (OR LOSS)
OF EXTERNALDEVICES PRECEDINGTHE AUT.
4. DEFAULT DISPLAY IS DUAL CHANNEL1-3 IN WHICH
CHANNEL1 = b2/1 [dBm] AND CHANNEL3 = S21.
1. AFTER THE AUT IS CONNECTED,NORMALIZES21.
2. INDICATE THE GAIN COMPRESSION POINT VALUE
(
x dB
)
AND SELECT <TEST AUT>.
3. INCREASE TEST PORT 1 POWER UNTIL A 1 dB (or x dB)
DECREASE IN S21 IS OBSERVED.
PORT1
PORT2
AMP
ATTN
TEST PORTS
ATTN
1
2
NOMINAL OFFSET
- SWEPTFREQUENCY GAIN COMPRESSION-
- CALIBRATION INSTRUCTIONS -
- MEASUREMENT INSTRUCTIONS -
Menu EXT_GC1, Gain Compression Help Menu 1