14-7
OPERATION
The 371XXCmm is menu driven and the millimeter wave operation is
entered into via the Enhancement Key-Group’s Options Menu key .
Selecting Millimeter Wave BAND DEFINITION in that menu pro-
vides for defining measurement parameters; selecting TEST SET
CONFIGprovides for configuring the 3735B Test Set parameters (Fig-
ure 14-4).
The menu options shown in the Figure 14-3 menus are described in
Appendix A, along with all of the other 371XXC menus. Additional op-
erating instructions are provided below.
Entering/ LeavingMillimeter
Wave Operation
Before entering the Millimeter Wave mode, users should have com-
pleted all of the steps in the “Installation” section of this manual. The
system should be ready for operation, with all connections properly
made to the Millimeter Wave test set, modules, and frequency synthe-
sizers. The system should then be powered up, and the procedure be-
low followed.
NOTE
Until the Millimeter Wave configuration is activated, the
system will not operate and it will fail to lock.
CAUTION
The transition to or from Millimeter Wave operation is a
major setup change that does NOT preserve the previous
setup. All current set up and RF calibration information
will be lost on entering or leaving the Millimeter Wave
mode configuration. If the existing setup needs to be
saved, this should be done before the system is reconfig-
ured for Millimeter Wave mode operation.
When the millimeter wave band is selected, the system automatically
reconfigures itself to measure at that frequency range. The lower and
upper limits of the displayed sweep frequencies will change to the
band selected. The frequency resolution changes to account for multi-
plier factors. However, users will (1) have access to the multiple source
control definitions and (2) be able to change the sweep frequencies as
desired.
The first step is to press the Options button on the front panel. This
brings up the Menu OPTNS (top left). Select TEST SET CONFIG.
This causes the Menu OTS1 (bottom left) to appear.
37XXXC OM
14-13
MILLIMETER WAVE
OPERATION
MENU OTS1
TEST SET
CONFIGURATION
INTERNAL
MILLIMETER WAVE
MENU OPTNS
OPTIONS
TRIGGERS
REAR PANEL
OUTPUT
Millimeter Wave
BAND DEFINITION
RECEIVER MODE
SOURCE CONFIG
TEST SET CONFIG
Summary of Contents for 37 C Series
Page 3: ......
Page 4: ......
Page 18: ...Figure 1 1 Model 37XXXC Vector Network Analyzer System...
Page 32: ......
Page 41: ......
Page 61: ...Intentionally Blank...
Page 97: ......
Page 103: ......
Page 223: ......
Page 242: ...37XXXC OM 9 21 9 22 TIME DOMAIN MENU FLOWCHART Figure 9 25 Time Domain Menu Flow...
Page 276: ......
Page 323: ......
Page 567: ......