Water Meter and Meter Plug
ITeM nO.
Order nO.
deScrIPTIOn
QTY.
1
102141
Nut 1” QC
1
2-4
102051*
Meter Assy.
1
3
102687
Turbine Assy.
1
4
102165
O
‑
ring 215
1
5
102321
Meter Plug Assy.**
1
*Order number 102051 includes 102687 and 102165, which are item
numbers 3 & 4.
**Only used if metering is
not
to be done (time clock units)
The nuts and caps are designed to be unscrewed or tightened by hand or
with the special plastic wrench. If necessary a pliers can be used to un
-
screw the nut or cap. Do not use a pipe wrench to tighten or loosen nuts
or caps. Do not place screwdriver in slots on caps and/or tap with a
hammer.
Figure 19
bypass Valve
Bypass Valve
ITeM nO.
Order nO.
deScrIPTIOn
QTY
1
102141
Nut 1" Quick Connect
2
2
102437
Split Ring
2
3
102165
O'Ring 215
2
4
102450
Bypass 1" Rotor
2
5
V3146
Bypass Cap
2
6
V3147
Bypass Handle
2
7
109479
Bypass Rotor Seal Retainer
2
8
102159
O
‑
Ring 135
2
9
102161
O
‑
Ring 112
2
10
102160
O
‑
Ring 214
2
(not Shown) bypass Vertical adapter assembly
Order nO. deScrIPTIOn
QTY
102141
Nut 1" Quick Connect
2
102437
Split Ring
2
102165
O'Ring 215
2
106858
Bypass Verticle Adapter
2
The nuts and caps are designed to be unscrewed or tightened by hand or with the
special plastic wrench. If necessary a pliers can be used to unscrew the nut or
cap. Do not use a pipe wrench to tighten or loosen nuts or caps. Do not place
screwdriver in slots on caps and/or tap with a hammer.
Do not use pipe dope or other sealants on threads. Teflon tape must be used on
threads of the 1” NPT connection and on the threads for the drain line
connection. Teflon tape is not necessary on the nut connection nor caps because
of o
‑
ring seals.
Figure 20