ANEP S-BOX
Version N° 3
11/06/2014
41
5.3.3 - erase a number
Enter the sequence : «
#
» then, the memory number, then «
#
»
Example : Erase the number and memory
101
# 101 #
note :
If no key is pressed for over 20 seconds, the unit plays a BEEP and returns to the start of the
memory selection part of the programming mode.
5.4 - Memory attribution
5.4.1 - transfer method
The S-BOX may be programmed to interface with the call center, utilizing the available software and
specifications.
To communicate with call centers, ANEP unit can transfer its ID information and establish a two-way
voice communication either :
• In a single calls,
• or two seperate call.
The recommanded method (with respect to European specifications), is to make a single call
(the delay time is optimized.
5.4.2 the table below shows the programming possibilities for a single call.
5.5 - enabling and adjustment of parameters
5.5.1 - emergency elevator telephone button validation time ( default = 0,5 second )
In programming mode :
Enter sequence
#
3
0
2 #
and the time
10ths of a
second.
Followed by key «
#
»
Example : 4.5 second timeout
Enter the sequence
#
302 45
#
Telephone N°
Type of data
Type of communication
Call center
Memory # 101
Passenger and tech alarm
Data & audio
Main call center
Memory # 102
Passenger and tech alarm
Data & audio
Backup call center
Memory # 103
Passenger and tech alarm
Data & audio
Backup call center
Memory # 104
Remote end of alarm
Data
Main call center
Memory # 105
Periodic call
Data
Call center for periodics calls
Memory # 106
Alarm data
Data
ANEPanywhere or client call center