ANEP S-BOX
Version N° 3
11/06/2014
42
5.5.2 - Acknowledgement of a trapped passenger ( en81-28 )
When this function is enabled, a call dialed by
S-BoX
must be acknowledged by the
operator by entering the sequence "
#
" then "
1
" on his telephone keypad during the
conversation.
If the acknowledgement is not made, then
S-BoX
will call back the center up to 6 times.
to enable this function,
In programming mode
Enter the sequence
#
2
0
2
#
The acknowledge function is enabled (default value = disable)
to disable the call acknowledgement
Enter the sequence
#
2
0
3
#
The acknowledge function is disabled.
5.5.3 - Conversation timeout
Conversation timeout from
1
to
99
minutes (factory default=
3
minutes)
In programming mode :
Enter the sequence :
# 2 0 1 #
Then enter conversation timeout ( from
1
to
99
) followed by " # "
#1
E
Function enabled
Function disabled
Do not do anything.
Enter the sequence « # » then
« 1 » on the phone heypad.