6 Troubleshooting
See "Safety tips for maintenance and repairs" on
page 41 before beginning troubleshooting.
For any other issues, please contact your dealer or
our technical service department.
6.1 Common problems
Problem
Possible cause
Solution
The mixing auger
(s) are no longer
turning.
The mixing auger (s) were
overloaded and the shear
bolt broke.
Replace the shear bolt (see "Replacing the
shear bolts" on page 90).
The shear bolts
break often.
The scrapers at the bottom
of the augers are not adjus-
ted properly.
Adjust or replace the scrapers (see "Adjust-
ing or replacing the auger scrapers" on
page 116).
The restrictor blades are too
far inside the mixing cham-
ber.
Reduce the travel of the restrictor blades
using the stroke limiter bolt (see "Adjusting
the cut size" on page 64).
The mixing augers
will not turn. The
shear bolt breaks
every time.
A mixing auger is blocked.
1. Engage the two- speed gearbox at
low speed.
2. Remove the restrictor blades from
the mixing chamber.
3. Open the unloading hatch (es). For
twin-
or
triple- auger
mixers,
disengage the PTO for the second
mixing auger.
The scale is defect-
ive.
There is a problem with the
scale system.
Contact your dealer.
Summary of Contents for SMARTMIX A1230FD
Page 1: ...Mixer SMARTMIX 404623 Operator s Manual ORIGINAL NOTICE 2019 ...
Page 2: ......
Page 8: ......
Page 10: ......
Page 14: ......
Page 17: ...Anderson Group Mixer Operator s Manual 15 Figure 3 SMARTMIX Auger ...
Page 22: ...20 Operator s Manual Mixer Anderson Group 1 2 2 SMARTMIX FD Figure 5 Dimensions SMARTMIX FD ...
Page 48: ......
Page 86: ......
Page 128: ......