42
Operator's Manual – Mixer
Anderson Group
2.4.4 Hydraulic
A pressurized oil leak can penetrate the skin and
cause serious injury. In the event of injury, see a
physician immediately to prevent serious infection.
Do not use your hands to locate leaks in a hydraulic
line.
l
Turn off the engine and remove the key from the ignition before beginning work on the
hydraulic system.
l
Before working on the hydraulic system, ensure that it is not pressurized. Relieve the pressure
before disconnecting the hydraulic lines.
l
Before repressurizing the hydraulic lines, ensure that all the couplings are correctly tightened.
l
Check the hydraulic lines regularly and replace them if they are damaged.
l
The replacement lines must meet the manufacturer's technical requirements.
2.4.5 Tires
l
Tire repairs must be performed by qualified personnel equipped with the appropriate tools.
l
If the air pressure is too high, the tires may explode. Use the recommended air pressure (see
"Technical specifications" on page 16).
l
Ensure that the machine is immobilized, stable and protected against accidental movement
before beginning work on the wheels. Use chocks and ensure that the lifting equipment has
sufficient lifting capacity.
2.4.6 Repairs
l
Replace worn parts with genuine parts.
l
Eliminate any defects that may compromise safety.
l
Immediately repair any leaks or damage to the equipment's hydraulic system.
l
Do not use your fingers to search for a (pressurized) hydraulic oil leak. Instead, use an object,
such as a piece of cardboard, to find the source of the leak.
l
Immediately replace any damaged or defective guards or locks. Original guards affixed to the
machine must not be removed or modified.
l
The hoses must not come from piping used in another system.
l
Immediately replace any damaged hoses.
2.4.7 Mixing chamber
Before beginning work:
l
Turn off the engine and remove the key from the ignition.
l
Put the gearshift in neutral and apply the handbrake.
l
Disengage the PTO and uncouple the drive shaft from the PTO.
l
Disconnect the hydraulic supply hoses.
Summary of Contents for SMARTMIX A1230FD
Page 1: ...Mixer SMARTMIX 404623 Operator s Manual ORIGINAL NOTICE 2019 ...
Page 2: ......
Page 8: ......
Page 10: ......
Page 14: ......
Page 17: ...Anderson Group Mixer Operator s Manual 15 Figure 3 SMARTMIX Auger ...
Page 22: ...20 Operator s Manual Mixer Anderson Group 1 2 2 SMARTMIX FD Figure 5 Dimensions SMARTMIX FD ...
Page 48: ......
Page 86: ......
Page 128: ......