Terminal (Program Port/Telnet) Commands
109
NI Series WebConsole & Programming Guide
Terminal Commands (Cont.)
Command
Description
SET URL <D:P:S>
Sets the initiated connection list URLs of a device.
Enter the URL address and port number of another Master or device
(that will be added to the URL list).
• Enter Y (yes) to approve/store the new addresses in the Master.
• Enter N (no) to cancel the operation.
Example:
>SET URL [0:1:0]
No URLs in the URL connection list
Type A and Enter to Add a URL or Enter to exit.
> a
Enter URL -> 192.168.21.200
Enter Port or hit Enter to accept default (1319) ->
Enter Type (Enter for permanent or T for temporary) ->
URL Added successfully.
SHOW BUFFERS
Displays a list of various message queues and the number of buffers
in each queue
Example:
show buffers
Thread TX RX Queued
----------- ---- ---- ----
Axlink 0
UDP 0 0-Sent=NO Waiting=NO
IPCon Mgr 0
Con Manager 0
Interpreter 0
Device Mgr 0
Diag Mgr 0
Msg Dispatch 0
Cfg Mgr 0
Route Mgr 0
Notify Mgr 0
---- ---- ----
Total 0 0 0 GrandTotal 0
Note
: See SHOW MAX BUFFERS.
SHOW COMBINE
Displays a list of devices, levels, and channels that are currently
combined.
Example:
> SHOW COMBINE
Combines
--------
Combined Device([33096:1:1],[96:1:1])
Combined Level([33096:1:1,1],[128:1:1,1],[10128:1:1,1])
Combined Device([33128:1:1],[128:1:1],[10128:1:1])
SHOW DEVICE <D:P:S>
Displays a list of devices present on the bus, with their device
attributes.
Example:
>SHOW DEVICE [0:1:0]
Local devices for system #1 (This System)
-------------------------------------------------------------------
---------
Device (ID)Model (ID)Mfg FWID Version
00000 (00256)NXC-ME260/64M (00001)AMX Corp. 00336
v3.00.312
(PID=0:OID=0) Serial=0,0,0,0,0,0,0,0,0,0,0,0,
Physical Address=NeuronID 000531589201
(00256)vxWorks Image (00001) 00337
v3.00.312
(PID=0:OID=1) Serial=N/A
(00256)BootROM (00001) 00338
v3.00.312
(PID=0:OID=2) Serial=N/A
(00256)AXlink I/F uContr(00001) 00270
v1.03.14
(PID=0:OID=3) Serial=0000000000000000
Summary of Contents for NetLinx Master-Ethernet Card/Module NXC-ME260
Page 8: ...vi NI Series WebConsole Programming Guide Table of Contents ...
Page 13: ...Overview 5 NI Series WebConsole Programming Guide ...
Page 14: ...Overview 6 NI Series WebConsole Programming Guide ...
Page 34: ...Onboard WebConsole User Interface 26 NI Series WebConsole Programming Guide ...
Page 36: ...WebConsole WebControl Options 28 NI Series WebConsole Programming Guide ...
Page 88: ...WebConsole System Options 80 NI Series WebConsole Programming Guide ...
Page 104: ...Programming 96 NI Series WebConsole Programming Guide ...
Page 156: ...Appendix A IPSec Configuration File 148 NI Series WebConsole Programming Guide ...
Page 161: ...Terminal Program Port Telnet Commands 153 NI Series WebConsole Programming Guide ...