background image

Software Warranty Agreement

GRANT OF LICENSE. AMX Corporation grants to you the right to use the enclosed 

IRLIB Infrared Library Manage-

ment 

software program (the SOFTWARE) on a single central processing unit (CPU). This license is for object code 

only and does not convey any rights to use of the source code.

This Agreement does not authorize you to distribute the SOFTWARE.

COPYRIGHT. The SOFTWARE is owned by AMX Corporation, and is protected by United States copyright laws and 
international treaty provisions. Therefore, you must treat the SOFTWARE like any other copyrighted material (e.g., a 
book or musical recording) except that you may either (a) make one copy of the SOFTWARE solely for backup or archi-
val purposes, or (b) transfer the SOFTWARE to a single hard disk provided you keep the original solely for backup or 
archival purposes. You may not copy the written materials accompanying the SOFTWARE.

OTHER RESTRICTIONS. You may not rent or lease the SOFTWARE, but you may transfer the SOFTWARE and 
accompanying written materials on a permanent basis provided you retain no copies and the recipient agrees to the 
terms of this Agreement. You may not reverse engineer, decompile, or disassemble the SOFTWARE. If the SOFT-
WARE is an update or has been updated, any transfer must include the most recent update and all prior versions.

You may use only one version of the SOFTWARE at any time. You may not use the version of the SOFTWARE not 
being run on your CPU on any other CPU or loan, rent, lease or transfer them to another user whether with or without 
consideration.

LIMITED WARRANTY

LIMITED WARRANTY. AMX Corporation warrants that the SOFTWARE will perform substantially in accordance with 
the accompanying written materials for a period of ninety (90) days from the date of receipt. Any implied warranties on 
the SOFTWARE and hardware are limited to ninety (90) days and one (1) year, respectively. Some states/countries do 
not allow limitations on duration of an implied warranty, so the above limitation may not apply to you.

CUSTOMER REMEDIES. AMX Corporation’s entire liability and your exclusive remedy shall be, at AMX Corporation's 
option, either (a) return of the price paid, or (b) repair or replacement of the SOFTWARE that does not meet AMX Cor-
poration's Limited Warranty and which is returned to AMX Corporation. This Limited Warranty is void if failure of the 
SOFTWARE or hardware has resulted from accident, abuse, or misapplication. Any replacement SOFTWARE will be 
warranted for the remainder of the original warranty period or thirty (30) days, whichever is longer. 

NO OTHER WARRANTIES. AMX Corporation disclaims all other warranties, either expressed or implied, including, but 
not limited to implied warranties of merchantability and fitness for a particular purpose, with regard to the SOFTWARE, 
the accompanying written materials, and any accompanying hardware. This limited warranty gives you specific legal 
rights. You may have others which vary from state/country to state/country.

NO LIABILITY FOR CONSEQUENTIAL DAMAGES. In no event shall AMX Corporation be liable for any damages 
whatsoever (including, without limitation, damages for loss of business profits, business interruption, loss of business 
information, or any other pecuniary loss) arising out of the use of or inability to use this AMX Corporation product, even 
if AMX Corporation has been advised of the possibility of such damages. Because some states/countries do not allow 
the exclusion or limitation of liability for consequential or incidental damages, the above limitation may not apply to you.

U.S. GOVERNMENT RESTRICTED RIGHTS

The SOFTWARE and documentation are provided with RESTRICTED RIGHTS. Use, duplication, or disclosure by the 
Government is subject to restrictions as set forth in subparagraph (c)(1)(ii) of The Rights in Technical Data and Com-
puter Software clause at DFARS 252.227-7013 or subparagraphs (c)(1) and (2) of the Commercial Computer Soft-
ware--Restricted Rights at 48 CFR 52.227-19, as applicable. Manufacturer is AMX Corporation, 3000 Research Drive, 
Richardson, TX  75082.

If you acquired this product in the United States, this Agreement is governed by the laws of the State of Texas.

Should you have any questions concerning this Agreement, or if you desire to contact AMX for any reason, please 
write: 

AMX Corporation, 3000 Research Drive, Richardson, TX  75082

.

Summary of Contents for IRLIB

Page 1: ...instruction manual Software IRLIB Infrared Library Management Program Version 2 01 or higher...

Page 2: ...iability and your exclusive remedy shall be at AMX Corporation s option either a return of the price paid or b repair or replacement of the SOFTWARE that does not meet AMX Cor poration s Limited Warra...

Page 3: ...ROM 5 Running IRLIBX from the AMX Control Disc folder 5 Menus and Options 7 Screen Saver Mode 8 Function Menus 9 F1 Hand control 9 F2 Function 10 F3 DCU IRS 11 F4 IRIS 13 F5 Communications 13 F6 Help...

Page 4: ...ii Table of Contents IRLIB Infrared Library Management Program IR Functions and Cable Diagrams 31 Hand Control IR Functions Standard Order 31 Cables and Adapters 32 RJ 25 Module Connectors 32...

Page 5: ...nt to any controllable device Minimum System Requirements Your computer must have MS DOS version 2 1 or higher installed to run the IRLIBX program IRLIBX requires a minimum 640 KB of memory RAM or hig...

Page 6: ...2 Introduction IRLIB Infrared Library Management Program...

Page 7: ...drive A or B At the MS DOS prompt type the floppy drive letter followed by a A or B and press Enter to reset the drive location 2 Type INSTALL and press Enter Read the INSTALL TXT message that appear...

Page 8: ...Click Next on the Control Disc Information screen 6 Read through the License Agreement page and if you agree to the terms click I AGREE If you do not agree to the terms you will be prompted with a scr...

Page 9: ...AMX DOS Tools folder that contains programs such as IRLIB AXCESSX and TPDesign3 5 Follow the on screen installation instructions When you are done click FINISH and restart your machine Running IRLIBX...

Page 10: ...6 Installation IRLIB Infrared Library Management Program...

Page 11: ...se This may cause a short delay before accessing any of the program menus or functions After the database is created IRLIBX produces another screen This is the main operating screen that includes menu...

Page 12: ...information refer to IRLIBX Menus and Options F5 Communication Settings Also refer to IR Functions and Cable Diagrams Screen Saver Mode Menus are selected by pressing the associated F key as shown at...

Page 13: ...previously saved Hand Control function files Press ENTER to select ESCAPE to return The selected file information will appear in the space under Currently selected hand con trol Rename Displays a Choo...

Page 14: ...ey to open the Version screen Exit ctrl x Highlighting this option and pressing return stops the IRLIBX program and returns you to the command line prompt Another way to exit is to press the control a...

Page 15: ...ist can then be programmed into any Panja IR devices The list you make can include all the functions or any subsets of the function lists of selected controllers This procedure is described in the App...

Page 16: ...eared first then reprogrammed Memory Checks the amount of memory remaining in an Panja IR device Provides a measure of the storage space left for additional Hand Control functions Verify Compares a DC...

Page 17: ...and Use section in this manual Capture Existing Menu option for appending changing or deleting Hand Control functions from an existing function file View Used for Panja internal use only F5 Communica...

Page 18: ...selected from the Choose selection box The Choose se lection box appears in three places of the IRLIBX program Selection is determined from either the Select option of the Hand Control menu or the Loa...

Page 19: ...ll up or down keys to highlight and select the Hand Control file then press the ENTER key to open the file View File Information After highlighting a Hand Control file in the Choose selection box use...

Page 20: ...select the Hand Control files you want to compare against the custom file you loaded or the IRIS function to be identi fied Figure 16 For more information on using custom files refer to the Building...

Page 21: ...press the ENTER key IRLIBX compares the marked files against the custom file you loaded or the IRIS function captured Note Custom file naming follows the convention NAME DEV FILE TYPE Using this namin...

Page 22: ...18 IRLIB Menus and Options IRLIB Infrared Library Management Program...

Page 23: ...highlight the CAPTURE NEW option 2 Press the ENTER or RETURN key to open begin opening the windows that ap pear in Figure 17 3 The ENTER MANUFACTURER window appears Figure 17 Enter up to 31 character...

Page 24: ...ill continue to wait for the incoming signal 9 After capturing the first function on the IRIS unit press the SEND key on the IRIS If no function is captured reconfirm that your connections and setting...

Page 25: ...captured the IR functions from your Hand Controls and built your Hand Control function library you can now make selected lists of the IR functions Connect an AXCESS card cage or other Panja IR device...

Page 26: ...arrow to move to the right column 6 Highlight the function choice to be stored to the previously selected function po sition on the left The function that you choose in the right column will now be m...

Page 27: ...les but may use any file nomen clature desired such as SAV Create a custom file from any IR function description list with the following steps 1 After storing the last IR function press ESCAPE You are...

Page 28: ...t can also be saved as a new file Load a custom file in order to program an AXC IR S card To load a custom file 1 Select the LOAD option from the DCU IRS menu 2 When the Load DCU IRS data screen appea...

Page 29: ...to the loaded custom file IRLIBX compares the tagged files against the hand con trol functions you copied to the custom file and fills in the function labels once it has a match from another compared...

Page 30: ...e selected files If the function labels were found then they are displayed If the function la bels are not found from the list of selected files the function position dis plays UNKNOWN Figure 25 You m...

Page 31: ...tem Highlight the PROGRAM option in the menu and press ENTER or RETURN If you are connected to a Central Controller the Enter Device Number message window Figure 26 appears Programming first clears th...

Page 32: ...enced by the IRLIBX program Depending on the menu selected and the option used you may see one or more of the operating messages Figure 28 or error messages Figure 29 Operating Messages Message Type M...

Page 33: ...ress Any Key No hand control was loaded for the option se lected Select a hand control from the Choose menu No Hand Control Loaded Window displayed if no hand control was loaded for the option selecte...

Page 34: ...30 Application and Use IRLIB Infrared Library Management Program...

Page 35: ...e up or 4 fwd 25 volume down or 5 rewind 26 mute 6 search fwd AMS music search fwd for CD 27 on power typically 7 search rev AMS music search rev for CD 28 off power typically 8 record 29 TV Video or...

Page 36: ...le Connectors The following cables will typically use 6 wire modular telephone style cable Figure 33 When using the RJ 25 modular connectors shown in the three SX type computer cables Figure 33 Figure...

Page 37: ...end similar to the illustration in the note above Then cross connect the yellow wire to the black wire within the length of the cable Figure 34 Computer to SX DCU DB 25 to RJ 25 wiring diagram Figure...

Page 38: ...s 3000 research drive richardson TX 75082 USA 469 624 8000 800 222 0193 fax 469 624 7153 technical support 800 932 6993 033 004 0428 7 01 2001 AMX Corporation All rights reserved AMX the AMX logo the...

Reviews: