background image

 

IRLIB Infrared Library Management Program 

Application and Use 

21 

 

 

11. 

Press return and continue building your Hand Control function file as indicated 
in steps 7 through 10. 

After capturing all of the functions with the IRIS unit and storing them with IRLIBX, 
press ESC (escape) to end the process for the current Hand Control.  

• 

To start another Hand Control function file: 

− 

Save the current file by pressing the ESC button. This causes IRLIBX to 
save the file with an .IRL extension. 

− 

Select CAPTURE NEW again.  

• 

If you want to add more functions to the current Hand Control list, use the 
CAPTURE EXISTING menu option. 

Building a Function Description List 

Once you have captured the IR functions from your Hand Controls, and built your 
Hand Control function library, you can now make selected lists of the IR functions. 
Connect an AXCESS card cage or other Panja IR device to your PC’s RS–232 commu-
nication port, and run the IRLIBX program. Use F3 to select the DCU/IRS menu and 
choose the MODIFY option to open the modify option window (Figure 20).  

These steps for developing and using an IR function description list are as follows: 

 

 

Figure 19  

Function was Loaded window 

Note

 

Attempting to enter a dupli-

cate function will cause an 

error window to be displayed. 

You can then select whether 

or not you really want a dupli-

cate function. 

Note  

If you are creating a custom 

file, follow the procedures in 

the 

Saving a Custom File 

subsection. Only use the 

Save File option to save cus-

tom files. Capturing 

is not 

used to save custom files. 

Summary of Contents for IRLIB

Page 1: ...instruction manual Software IRLIB Infrared Library Management Program Version 2 01 or higher...

Page 2: ...iability and your exclusive remedy shall be at AMX Corporation s option either a return of the price paid or b repair or replacement of the SOFTWARE that does not meet AMX Cor poration s Limited Warra...

Page 3: ...ROM 5 Running IRLIBX from the AMX Control Disc folder 5 Menus and Options 7 Screen Saver Mode 8 Function Menus 9 F1 Hand control 9 F2 Function 10 F3 DCU IRS 11 F4 IRIS 13 F5 Communications 13 F6 Help...

Page 4: ...ii Table of Contents IRLIB Infrared Library Management Program IR Functions and Cable Diagrams 31 Hand Control IR Functions Standard Order 31 Cables and Adapters 32 RJ 25 Module Connectors 32...

Page 5: ...nt to any controllable device Minimum System Requirements Your computer must have MS DOS version 2 1 or higher installed to run the IRLIBX program IRLIBX requires a minimum 640 KB of memory RAM or hig...

Page 6: ...2 Introduction IRLIB Infrared Library Management Program...

Page 7: ...drive A or B At the MS DOS prompt type the floppy drive letter followed by a A or B and press Enter to reset the drive location 2 Type INSTALL and press Enter Read the INSTALL TXT message that appear...

Page 8: ...Click Next on the Control Disc Information screen 6 Read through the License Agreement page and if you agree to the terms click I AGREE If you do not agree to the terms you will be prompted with a scr...

Page 9: ...AMX DOS Tools folder that contains programs such as IRLIB AXCESSX and TPDesign3 5 Follow the on screen installation instructions When you are done click FINISH and restart your machine Running IRLIBX...

Page 10: ...6 Installation IRLIB Infrared Library Management Program...

Page 11: ...se This may cause a short delay before accessing any of the program menus or functions After the database is created IRLIBX produces another screen This is the main operating screen that includes menu...

Page 12: ...information refer to IRLIBX Menus and Options F5 Communication Settings Also refer to IR Functions and Cable Diagrams Screen Saver Mode Menus are selected by pressing the associated F key as shown at...

Page 13: ...previously saved Hand Control function files Press ENTER to select ESCAPE to return The selected file information will appear in the space under Currently selected hand con trol Rename Displays a Choo...

Page 14: ...ey to open the Version screen Exit ctrl x Highlighting this option and pressing return stops the IRLIBX program and returns you to the command line prompt Another way to exit is to press the control a...

Page 15: ...ist can then be programmed into any Panja IR devices The list you make can include all the functions or any subsets of the function lists of selected controllers This procedure is described in the App...

Page 16: ...eared first then reprogrammed Memory Checks the amount of memory remaining in an Panja IR device Provides a measure of the storage space left for additional Hand Control functions Verify Compares a DC...

Page 17: ...and Use section in this manual Capture Existing Menu option for appending changing or deleting Hand Control functions from an existing function file View Used for Panja internal use only F5 Communica...

Page 18: ...selected from the Choose selection box The Choose se lection box appears in three places of the IRLIBX program Selection is determined from either the Select option of the Hand Control menu or the Loa...

Page 19: ...ll up or down keys to highlight and select the Hand Control file then press the ENTER key to open the file View File Information After highlighting a Hand Control file in the Choose selection box use...

Page 20: ...select the Hand Control files you want to compare against the custom file you loaded or the IRIS function to be identi fied Figure 16 For more information on using custom files refer to the Building...

Page 21: ...press the ENTER key IRLIBX compares the marked files against the custom file you loaded or the IRIS function captured Note Custom file naming follows the convention NAME DEV FILE TYPE Using this namin...

Page 22: ...18 IRLIB Menus and Options IRLIB Infrared Library Management Program...

Page 23: ...highlight the CAPTURE NEW option 2 Press the ENTER or RETURN key to open begin opening the windows that ap pear in Figure 17 3 The ENTER MANUFACTURER window appears Figure 17 Enter up to 31 character...

Page 24: ...ill continue to wait for the incoming signal 9 After capturing the first function on the IRIS unit press the SEND key on the IRIS If no function is captured reconfirm that your connections and setting...

Page 25: ...captured the IR functions from your Hand Controls and built your Hand Control function library you can now make selected lists of the IR functions Connect an AXCESS card cage or other Panja IR device...

Page 26: ...arrow to move to the right column 6 Highlight the function choice to be stored to the previously selected function po sition on the left The function that you choose in the right column will now be m...

Page 27: ...les but may use any file nomen clature desired such as SAV Create a custom file from any IR function description list with the following steps 1 After storing the last IR function press ESCAPE You are...

Page 28: ...t can also be saved as a new file Load a custom file in order to program an AXC IR S card To load a custom file 1 Select the LOAD option from the DCU IRS menu 2 When the Load DCU IRS data screen appea...

Page 29: ...to the loaded custom file IRLIBX compares the tagged files against the hand con trol functions you copied to the custom file and fills in the function labels once it has a match from another compared...

Page 30: ...e selected files If the function labels were found then they are displayed If the function la bels are not found from the list of selected files the function position dis plays UNKNOWN Figure 25 You m...

Page 31: ...tem Highlight the PROGRAM option in the menu and press ENTER or RETURN If you are connected to a Central Controller the Enter Device Number message window Figure 26 appears Programming first clears th...

Page 32: ...enced by the IRLIBX program Depending on the menu selected and the option used you may see one or more of the operating messages Figure 28 or error messages Figure 29 Operating Messages Message Type M...

Page 33: ...ress Any Key No hand control was loaded for the option se lected Select a hand control from the Choose menu No Hand Control Loaded Window displayed if no hand control was loaded for the option selecte...

Page 34: ...30 Application and Use IRLIB Infrared Library Management Program...

Page 35: ...e up or 4 fwd 25 volume down or 5 rewind 26 mute 6 search fwd AMS music search fwd for CD 27 on power typically 7 search rev AMS music search rev for CD 28 off power typically 8 record 29 TV Video or...

Page 36: ...le Connectors The following cables will typically use 6 wire modular telephone style cable Figure 33 When using the RJ 25 modular connectors shown in the three SX type computer cables Figure 33 Figure...

Page 37: ...end similar to the illustration in the note above Then cross connect the yellow wire to the black wire within the length of the cable Figure 34 Computer to SX DCU DB 25 to RJ 25 wiring diagram Figure...

Page 38: ...s 3000 research drive richardson TX 75082 USA 469 624 8000 800 222 0193 fax 469 624 7153 technical support 800 932 6993 033 004 0428 7 01 2001 AMX Corporation All rights reserved AMX the AMX logo the...