SWT Troubleshooting
80
Metreau Keypads
Zone Connection Problems
If there is wall power and both the source components and the Controller seem to be powering up OK,
but one or more of the zones are not working, there may be a problem at the individual zone or with the
cabling connecting to the zone. Begin by checking each zone keypad for functionality by pressing the
desired source button. The LED should light red next to the source on the KP-4e keypads or should
“wake up” with a screen menu on the touch panel keypad.
Dead Zones
There is power and the source devices and the Tango Controller seem to be powering up OK, but one or
more of the zones are not working.
Check each zones keypad for functionality by pressing the desired source button. The LED should light
Red next to the source.
LED Does Not light
You are not getting power and command connectivity to the zone. Check other zones and select each
source to determine if this is specific to the source or the room in general. If the problem is in a particular
room then there may be an issue with cabling to your speakers or it may be the keypad itself. If you get
similar results for a particular source in multiple zones then there may be an issue with the source
equipment and you should check to see that the selected source is ‘playing’. If every other zone is ok,
check to make sure cables to the speakers are secure and that you have tried to increase the volume level
in the zone.
Possible Causes:
Zone connectors at Tango Controller are not secure.
Connector at Keypad to Tango Controller is not secure.
Wiring standard not followed. Make certain the center two wires are in the same orientation at
the Tango Controller and the keypad. They may have been inadvertently reversed during the
installation.
Input and output connectors on keypad are reversed.
Keypad not recognized by system. Restart system.
Source Connections
Problems in source cabling display some of the following characteristics.
The source cannot be heard in any zone.
The source doesn’t seem to respond to keypad commands.
Check the Following:
Ensure that the sources LINE OUT connections are connected to the Tango Controllers LINE IN
connections for the correct device. Check to see that the IR emitter lead is securely fastened to the IR
receiver on the audio source and that you have the lead plugged into the appropriate IR output jack
(
FIG. 41
)
.
When a keypad command is received and communicated to the source device, there is a LED that lights
on the front of the Tango Controller indicating the processing of the command. If the LED does not light
with a keypad press, then it is possible that the device has not been programmed. If the LED does light,
there may be a problem with the infrared emitter lead.
Tip
: For Testing, when you are having IR problems, it is helpful to carry a blinking
emitter or a test emitter to ensure that the commands are being sent to the source.
Techniques you can use to help isolate a sources problem include swapping the source
with another on the Tango Controller to see if the problem stays with the Controller or
Summary of Contents for DAS-MET-NUM
Page 7: ...Table of Contents v Metreau Keypads No Keypad Activity 81 Keypad Lights No Sound 81 ...
Page 8: ...vi Metreau Keypads Table of Contents ...
Page 36: ...Wiring and Connections 28 Metreau Keypads ...
Page 70: ...Advanced Functions DAS MET 6SRC 62 Metreau Keypads ...
Page 90: ...SWT Troubleshooting 82 Metreau Keypads ...
Page 91: ...Numeric Keypads Advanced Functions 83 Metreau Keypads ...