Wiring and Connections
21
Metreau Keypads
Using AxLink for Data with an Auxiliary Power Supply
Use an auxiliary 12 VDC power supply when the distance between the controller and server exceeds the
limits described in the
AxLink Wiring Guidelines
. Connect only the GND (-) wire on the AxLink
connector when using an auxiliary 12 VDC power supply.
Connect the NetLinx Controller’s AxLink connector to the AxLink connector on the rear panel of the
Metreau keypad, as shown in FIG. 19.
AxLink Status LED
The AxLink Status LED (located next to the AxLink connector), lights to indicate AxLink power/data
status as follows:
If the LED is on and not flashing, disconnect the AxLink connector and recheck all AxLink connections.
Then, reconnect the AxLink connector to the panel and verify the LED is flashing once per second.
FIG. 19
AxLink and 12 VDC power supply wiring diagram
12 VDC power supply
PWR (+)
AXP
AXM
GND (-)
Metreau keypad
NetLinx Controller
PWR (+)
AXP
AXM
GND (-)
PWR (+)
GND (-)
If you are not using power from AxLink, disconnect the wiring from the controller
before wiring the Metreau keypad. Make sure the auxiliary power supply’s PWR (+) is
not connected to the controller’s AxLink connector.
AxLink LED Status
• 1 blink per second:
Indicates power is active and AxLink communication is working.
• Full On:
Indicates the following conditions:
• There is no AxLink control or activity, but power is On.
• The Axcess program is not loaded.
Summary of Contents for DAS-MET-NUM
Page 7: ...Table of Contents v Metreau Keypads No Keypad Activity 81 Keypad Lights No Sound 81 ...
Page 8: ...vi Metreau Keypads Table of Contents ...
Page 36: ...Wiring and Connections 28 Metreau Keypads ...
Page 70: ...Advanced Functions DAS MET 6SRC 62 Metreau Keypads ...
Page 90: ...SWT Troubleshooting 82 Metreau Keypads ...
Page 91: ...Numeric Keypads Advanced Functions 83 Metreau Keypads ...