L0086, Rev. G
AMS SENSIT 3 GLASS FRONT VENDOR
7-2
ERROR CODES – CAUSES AND SOLUTIONS
TOP LEVEL
ERROR CODE
SUB LEVEL
CODE
CAUSES SOLUTIONS
BILL
VALIDATOR
A message has been generated by the bill validator.
Press
1
for bill validator sub-level error codes.
COMMUN
COMMUNICATIONS –
Communications error.
Check MDB harness connections.
STK FULL
STACKER FULL – Stacker is full.
Empty stacker.
MOTOR
MOTOR – Bad stacker motor.
Consult acceptor manual or manufacturer for repair.
JAM BILL
JAMMED BILL - Bill is jammed.
Clear any jammed bills from the acceptor.
CHK SUM
CHECK SUM – Check sum error.
Consult acceptor manual or manufacturer.
OPEN BOX
OPEN BOX – Open box.
Close the bill box.
SENSOR
SENSOR – Sensor error.
Consult acceptor manual or manufacturer.
CARD READER
A message has been generated by the card reader.
Press
1
to see sub-level error codes.
CARD ERROR –. Card error
Use a different card.
INVALID CARD – Invalid card
Use a different card
TAMPER
Tamper error.
Consult card reader manual or manufacture
COMMUNICATIO
NS 4
Communications error.
Check MDB harness connections
SERVICE
Unit needs service.
Consult card reader manual or manufacturer.
READ ERROR
Reader failure.
Consult card reader manual or manufacturer.
COMMUNICATIO
NS 9
Communications error
Check MDB harness connections.
JAMMED CARD Card is jammed.
Clear the jammed card from the card reader.
7.3 CLEARING JAMMED MOTOR
If one or more motors and helixes become jammed,
the motor(s) will be displayed as a sublevel error under
“Motor Jammed”.
Energized vend motors can turn a helix with
considerable torque, creating a possible entrapment
hazard. Disconnect power to the merchandiser or control
board before freeing a jammed helix or motor. Always
restrain or block the helix before freeing a jammed or
caught product.
CAUTION
:
Use caution when freeing jammed product!
Refer to 2.2.4 Helix Motion and Jamming!
Clear any jammed products from the indicated vend
columns.
To reset the error, first enter service mode (Refer to
Section 6.0), then select Tray Setup (Refer to Section
6.7.1). Press “1”, then “ * “, then “3”. The control will
attempt to run the jammed motors. If the motor had been
taken out of the motor matrix, it will be re-established in the
matrix.
Summary of Contents for Sensit 3 39 VRM
Page 2: ...L0086 Rev H AMS SENSIT 3 GLASS FRONT VRM ...
Page 6: ...L0086 Rev H AMS SENSIT 3 GLASS FRONT VRM iv ...
Page 16: ...L0086 Rev H AMS SENSIT 3 GLASS FRONT VRM 3 4 ...
Page 38: ......
Page 46: ...L0086 Rev G AMS SENSIT 3 GLASS FRONT VRM 9 2 Figure 9 1 Typical Wiring Diagram Sheet 2 of 2 ...
Page 50: ...L0086 Rev G AMS SENSIT 3 GLASS FRONT VRM 11 2 ...
Page 52: ...L0086 Rev G AMS SENSIT 3 GLASS FRONT VRM 12 2 ...