L0086, Rev. H
AMS SENSIT 3 GLASS FRONT VRM
2-2
certified recovery equipment. Unauthorized service to the
sealed refrigerant system will void the warranty.
1. Never puncture or cut any component in the
refrigeration system.
2. Always use licensed service technicians to service the
refrigeration system.
3. Always wear hand and eye protection when servicing
the merchandiser.
2.2.6 Vendor Tipping
The empty weight of the merchandiser is
approximately 750 pounds (340 kg). A falling merchandiser
can cause serious injury or death. Caution should always
be taken to avoid dropping or tipping a merchandiser.
1. Never rock or tip the merchandiser. It must be kept
horizontal for safe operation.
2. Never place the merchandiser in an inclined position,
such as on a ramp or with all the legs not on the same
horizontal surface.
3. Never place the merchandiser in a moving environment
such as on a ship without properly securing it in place.
4. Never place the merchandiser in a location where it may
be struck by a vehicle.
5. Never transport an unsecured merchandiser, or a
merchandiser still containing product.
6. Never attempt to lift or move the merchandiser by hand.
Always use equipment with the proper load rating. Note
that the Specification weight listed is empty weight.
2.2.7 Other Improper Conditions
Hazardous conditions can be created by improper
use or service of the merchandiser.
WARNING:
Do not use electrical appliances inside the
merchandiser unless recommended by AMS.
1. Always reinstall any parts removed during service to
their original locations.
2. Never make unauthorized modifications to any part of
the merchandiser.
3. Always replace components that are worn, broken, or
otherwise unfit for use.
4. Never use unauthorized parts, or use parts for anything
other than their intended application.
2.2.8 Ground Fault Circuit Interrupter
This merchandiser is equipped with a Ground
Fault Circuit Interrupter (GFCI), in compliance with
ANSI/UL 751 and 451, and is in compliance with UL 943.
2.3 TEST STANDARDS
AMS vending machines bearing the ETL mark
have been tested and comply with one of the following
standards:
2.3.1 ANSI/UL 541
Standard for Refrigerated Vending Machines
ANSI/UL 541and the Standard for Refrigeration
Equipment, CAN/CSA C22.2 No. 120
2.3.2 ANSI/UL 751
Standard for Safety for Vending Machines ANSI/UL
751 and the Standard for Vending Machines,
Consumer and Commercial Products (CAN/CSA
C22.2 No. 128
2.3.3 Additional Standards
Certain models comply with the following:
2.3.3.1 European Union
European Economic Area
CE (European Conformity)
2.3.3.2 2007 Appliance Efficiency
Regulations
CEC-400-2007-016-REV1
2.3.3.3 Natural Resources Canada (NRCan)
Energy Efficiency Regulations, OEE
2.3.3.4 Americans with Disabilities Act
Refer to Section 4.3.2.
Summary of Contents for Sensit 3 39 VRM
Page 2: ...L0086 Rev H AMS SENSIT 3 GLASS FRONT VRM ...
Page 6: ...L0086 Rev H AMS SENSIT 3 GLASS FRONT VRM iv ...
Page 16: ...L0086 Rev H AMS SENSIT 3 GLASS FRONT VRM 3 4 ...
Page 38: ......
Page 46: ...L0086 Rev G AMS SENSIT 3 GLASS FRONT VRM 9 2 Figure 9 1 Typical Wiring Diagram Sheet 2 of 2 ...
Page 50: ...L0086 Rev G AMS SENSIT 3 GLASS FRONT VRM 11 2 ...
Page 52: ...L0086 Rev G AMS SENSIT 3 GLASS FRONT VRM 12 2 ...