4.0 VENDOR PREPARATION AND INSTALLATION
Setting up the merchandiser has been divided
into three stages. Step 4.1 confirms power and site
suitability. Step 4.2 includes preparations accomplished in
the shop. Step 4.3 is accomplished on-site, where the
merchandiser is to be located.
4.1 CONFIRMING POWER AT OUTLET
4.1.1 Checking the Power (U.S. and Canada)
AMS recommends using a dedicated outlet which
can supply 15 to 20 amps per merchandiser.
Using a volt meter set to AC VOLTS, check the
voltage between the positive (smaller) lug entry and the
ground lug entry (or center screw on two-lug outlets). The
reading should be
between 103 volts and 126 volts
.
Next, check the voltage between the negative (larger) lug
entry and the ground. The reading should be
0 volts
. If
your results vary, contact a qualified electrician to correct
the outlet wiring before plugging in the merchandiser.
Abnormal voltage, reversed polarity or improper
grounding may cause the merchandiser to
malfunction or create hazardous conditions in the
merchandiser, resulting in possible injury, damage to
the merchandiser, or fire.
The power cord is shipped in the hopper on the
inside of the door. The cord is supplied with a standard
NEMA 3-wire plug. If there are no 3-wire outlets available
for powering the merchandiser, a grounding adapter may
be used to convert a 2-wire outlet to accept the 3-wire
plug.
The adapter must have a ground tab or wire
which must be fastened to the center screw of the
outlet
.
NEVER USE AN EXTENSION CORD
WITH THE MERCHANDISER.
4.1.2
Checking the Power (Outside the U.S. and
Canada)
Consult a qualified electrician to check the outlet for
proper polarity, voltage, and grounding. Check the serial
plate on the side of the door to confirm the merchandiser
is rated for the outlet voltage.
4.1.3 Electrical
Service Requirement for CE
Compliance
The following requirement applies only to models
using ½ HP compressors and displaying the CE mark on
the serial plate. If this requirement applies to your
merchandiser, you will find a similarly worded decal on the
back of the merchandiser near the power cord.
This requirement does not apply to any
merchandiser using 120V service.
ELECTRICAL SERVICE REQUIREMENT FOR CE
COMPLIANCE:
THIS EQUIPMENT IS INTENDED FOR USE ONLY IN
PREMISES HAVING A SERVICE CURRENT CAPACITY
OF AT LEAST 100A PER PHASE, SUPPLIED FROM A
DISTRIBUTION NETWORK HAVING A NOMINAL
VOLTAGE OF 400/230V. THE USER SHOULD
DETERMINE IN CONSULTATION WITH THE SUPPLY
AUTHORITY, IF NECESSARY, THAT THE SERVICE
CURRENT CAPACITY AT THE INTERFACE POINT IS
SUFFICIENT FOR THIS EQUIPMENT.
4.1.4 Requerimiento de Servicio Eléctrico para
Certificación CE
El siguiente requerimiento se aplica solamente a
los modelo utilicen compresores de ½ HP y que muestren
la marca CE en la placa de serie. Si este requerimiento se
aplica a su dispensadora, verá una calcomanía con una
terminología parecida en la parte posterior de la
dispensadora, cerca del cordón de corriente.
Este requerimiento no se aplica a dispensadoras
que utilizan un servicio de 120V.
REQUERIMIENTO DE SERVICIO ELECTRICO PARA
CERTIFICACION CE:
ESTE EQUIPO SE PUEDE UTILIZAR SOLAMENTE EN
ESTABLECIMIENTOS QUE CONTENGAN UNA
CAPACIDAD DE CORRIENTE DE SERVICIO DE POR
LO MENOS 100A POR FASE, Y SUMINISTRADOS POR
UNA RED DE DISTRIBUCION QUE CONTENGA UN
VOLTAJE NOMINAL DE 400/230V. EL USUARIO
DEBERA CONSULTAR CON UNA AUTORIDAD DE
SUMINISTRO, SI ES NECESARIO, PARA VERIFICAR
QUE LA CAPACIDAD DE CORRIENTE DE SERVICIO
EN EL PUNTO DE INTERFASE ES SUFICIENTE PARA
ESTE EQUIPO.
4.1.5 Les Utilites Electriques Necessaire Pour
Conformement Aux Regles CE
Le suivant condition applique seulement à
modèle en utilisant ½ HP compresseur et montrer le CE
sur l'en série plaque. Si cette condition s'applique à votre
vendeur, vous verrez un decal de même exprimé sur le
dos du vendeur près du cordon d'alimentation.
Cette condition ne s'applique pas au service de
120V d'utilisation de vendeur.
LES UTILITES ELECTRIQUES NECESSAIRE POUR
CONFORMEMENT
AUX REGLES CE:
CET EQUIPEMENT NE DOIT UTILISER QUE SUR LES
LIEUX AVEC UNE CAPACITE DU COURANT AU MOINS
100A LA PHASE, FOURNIE A UN RESEAU DE
DISTRIBUTION AVEC UN VOLTAGE NOMINAL DE
400/230V. LA PERSONNE QUI SE DETERMINER
PENDANT UNE CONSULTATION AVEC
L’ADMINISTRATION DU SECTEUR, S’IL FAUT, QUE LA
CAPACITE DE COURANT AU POINT D’INTERFACE
EST ASSEZ POUR CET EQUIPEMENT.
Summary of Contents for Sensit 3 39 VRM
Page 2: ...L0086 Rev H AMS SENSIT 3 GLASS FRONT VRM ...
Page 6: ...L0086 Rev H AMS SENSIT 3 GLASS FRONT VRM iv ...
Page 16: ...L0086 Rev H AMS SENSIT 3 GLASS FRONT VRM 3 4 ...
Page 38: ......
Page 46: ...L0086 Rev G AMS SENSIT 3 GLASS FRONT VRM 9 2 Figure 9 1 Typical Wiring Diagram Sheet 2 of 2 ...
Page 50: ...L0086 Rev G AMS SENSIT 3 GLASS FRONT VRM 11 2 ...
Page 52: ...L0086 Rev G AMS SENSIT 3 GLASS FRONT VRM 12 2 ...