AS7030B/AS7038GB/AS7038RB
Software Description
Eval Kit Manual
• PUBLIC
UG001014
• v1-00 • 2021-May-06
53
│ 43
Figure 46:
PD Offset & LED Current Control Submenu
Minimum amplitude of the controlled signal in ADC counts
– If the amplitude of the ADC signal drops
below that value, LED current will be increased, if LED current control is enabled.
Maximum amplitude of the controlled signal in ADC counts
– If the amplitude of the ADC signal grows
above that value, LED current will be decreased, if LED current control is enabled.
Number of samples to average
– How many ADC samples are averaged before values go to FIFO.
AGC reset interval
– The interval at which the min and max values are calculated over a moving
average are reset in order to keep a recent history and to avoid random spikes.