5.5 Alphanumeric Input
Three functions require not only numbers but also an input of letters:
1. Device designation or individual print header (40/24 characters)
2. Dimension for each measuring point (2 characters)
3. Measuring point designation for each measuring point (10 characters)
These parameters can, as the easiest method, be entered via the serial
interface using the AMR Control software or via any terminal (s. man. 6.2.4,
6.3.5, 6.3.6). The keyboard of the instrument can also be used for this. Apart
from the numbers printed on the keys, it is also possible to select the letters or
characters given at the right bottom by repeatedly operating the keys. The key
ENTER
has, for upper case letters and special characters (°,
Ω
, %, !) the
function of a SHIFT key
×
, and, for lower case letters, the function of the key
Ö
for moving the cursor to the next digit.
Individual Print Header / Device Designation
(see man. 6.2.4)
During measuring point scans the device designation appears as an individual
print header instead of the type designation "AMR ALMEMO 5590-2" (40
characters at max.) and in the display within the function MEAS.VALUE instead
of the device version (24 characters at max.). In case of several networked
devices it is used as a device designation and for an easier identification. As an
example, the following description describes the input of the word ´Text´.
Selection of the function
MEAS.VALUE
1. Press key
ENTER
, 1st digit after measuring point
flashes: Input measuring point designation, s. 6.4
0 0 0 0 :`_´_ _ _ _ _ _
2. Press key
Õ
, then the 1st digit of the device designation
flashes in the 2nd line
`_´_ _ _ _ _ _ _ _ _ _
3. Hold
ENTER
for capital letters
and press the required key, e.g.
0
ST
as often,
until the desired character appears:
`T´_ _ _ _ _ _ _ _ _ _
4. When the key
ENTER
is released
the next digit automatically starts flashing.
T`_´_ _ _ _ _ _ _ _ _ _
5. For lower case letters and numbers just press
the corresponding key,
e.g.
9
EF
, until the desired character appears:
T`e´_ _ _ _ _ _ _ _ _ _
6. A switch to the next digit is performed using the key
Ö
,
continue the input until the text is complete.
T e x`t´_ _ _ _ _ _ _ _
7. Complete the input with the key
Ö
and key
Ent
or Abort/Cancel with the key
Esc
Clear the designation
with the key
Ent
from the 1st digit.