2. INITIAL OPERATION
1. Connect the
transducers
to the sockets Mxx (8) and (9), see 4.
2. Ensure
power supply
by mains adapter connected to socket (7), see 3.1
3. For
switch-on
press the rocker switch (1), so the control lamp is on, s. 3.4
4. For
displaying
the measured values,
select function MEAS. VALUE by using the rotary switch (5),
select measuring channel with the key , read the meas. value, see 7.1.
5.
For storing
the measured values:
Use the function MEMORY and keys
ENTER
,
CLEAR
to clear the memory.
Use MEAS. CYCLE and the key
ON
to activate the memory, see 7.3.2.
Single storing with using the key
MANUAL,
see 7.2.
Enter measuring cycle for cyclic storing, see 7.3.2.
Enter time and date as required, see 7.3.4.
Enter time and date of start or end of a measurement as required, see 7.3.5.
Use the keys
START
and
STOP
to start and stop a cyclic storing, see 7.3.
Output of memory data to printer or computer
Connect peripheral device via interface cable to socket A1, see manual 5.2.
Set 9600 bd, 8 data bits, 1 stop bit, no parity at peripheral device, see 8.1.
Use the key in function OUTPUT CYCLE to set the output channel ´
U
´
and, possibly, use the key
CHANNEL
to set the output format columns ´
n
´ or
spreadsheet (table) ´
t
´, see 7.2.2.
Use key
within function MEMORY to output meas. values, see 7.4.2.
6.
Cyclic output of measured values
to printer or computer
Connect peripheral device via interface cable to socket A1, see manual 5.2.
Set 9600 bd, 8 data bits, 1 stop bit, no parity at peripheral device, see 8.1.
Enter time and date, as required, see 7.3.4.
Program the output cycle within function OUTPUT CYCLE,
with key
output channel ´
U
´ and, if required, with key
CHANNEL
set output format columns ´n´ or spreadsheet (table) ´t´, see 7.2.2.
Use the keys
START
and
STOP
to start and stop a cyclic storing, see 7.3.
7.
Monitoring of limit values
Enter limit values, see 6.5.
Program measuring cycle, see 7.3.2.
Connect alarm device with alarm module to socket A2, see man. 5.1.2/5.1.3
Use the key in function OUTPUT CYCLE to activate ´U´ for alarm list
output and ´S´ for storing the data of the output channel, see 7.2.2.
Use the keys
START
and
STOP
to start and stop a cyclic storing, see 7.3.
8.
Evaluation
of the measurement
Display max and min values within function MAX or MIN VALUE, see 7.1.2.
13
ALMEMO
®
5590-2
Initial Operation
Summary of Contents for Almemo 5590-2 V5
Page 54: ...53 ALMEMO 5590 2 Appendix...
Page 55: ...ALMEMO 5590 2 54 Notes...
Page 56: ...55 ALMEMO 5590 2 Notes...