3.2 PRODUCT SPECIFICATIONS
3.2.1 GENERATOR SPECIFICATIONS
Rated power…...................... 5KW (AG5500E);5.5KW(AG6500E)
;6KW(AG7500E);6.5KW(AG8500E);7.2KW(AG9500).
Surge. power..........................5.5KW(AG5500E);6KW(AG6500E)
;6.5KW(AG7500E);7.2KW(AG8500E);7.8KW(AG9500E).
Rated AC voltage…………………………………………..120/240V
Rated frequency……………..……………………60Hz@3600RPM
Phase…………………………………….….…………..single phase
**Maximum wattage is subject to, and limited by, such factors as
fuel Btu content temperature, altitude, engine condition,
etc...Maximum power decreases about 3.5% for each 1,000 feet
above sea level; and will also decrease about 1% for each 6
℃
(
10
℉)
above16
℃
(60
℉
)ambient temperature.
3.2.2 ENGINE SPECIFICATIONS
Displacement…………………..389cc(AG5500E/AG6500E);420cc
(AG7500E/AG8500E/AG9500E).
Spark plug type.….…F6TC,NGK BPR4ESor champion RN14YC.
Spark plug gap……………….0.028-0.031 inch or (0.70-0.80mm)
Gasoline capacity……………….…….........25L(6.42.U.S. gallons)
Oil type….……see chart in “before starting the generator” section
Oil capacity………………………………………….1.1L (0.634Qts)
Run time……………………………………....12 hours at 1/2 Load
class
Ⅱ
emission certified*
*The engine manufacturer must warrant the emission control
system for a period of one year. This warranty coverage is in
additions to the warranty provided by AMICO, and may cover
the engine even if AMICO’s warranty does not.
20