* While engine is still warm, drain oil from crankcase. Refill with
recommended grade.
* Remove spark plugs and pour about 1/2 ounce(15ml) of engine
oil into the cylinders. Cover spark plug hole with rag. Pull the
recoil starter a couple times to lubricate the piston rings and
cylinder bore.
Avoid spray from spark plug holes when
cranking engine.
* Install and tighten spark plugs. Do not connect spark plug wires.
* Clean the generator outer surfaces. Check that cooling air slots
and openings on generator are open and unobstructed.
* Store the unit in a clean, dry place.
3.8 OTHER STORAGE TIPS
* Do not store gasoline from one season to another.
* Replace the gasoline can if it starts to rust. Rust and /or dirt in
the gasoline will cause problems with the carburetor and fuel
system.
* If possible, store the unit indoors and cover it to give protection
from dust and dirt.
Be sure to empty the fuel tank.
* If it not practical to empty the fuel tank and the unit is to be
stored for some time, use a commercially available fuel
stabilizer added to the gasoline to increase the life of the
gasoline.
* Cover the unit with a suitable protective cover that does not
retain moisture.
Never cover the generator while engine and
exhaust area warm.
26
26
Summary of Contents for AG series
Page 32: ...AG5500 29...
Page 33: ...AG6500 30...
Page 34: ...AG9500 31...
Page 35: ...AG8500 32...
Page 36: ...AG7500 33...