*Use a damp cloth to wipe exterior surfaces clean.
*A soft, bristle brush may be used to loosen caked on dirt, oil, etc.
*A vacuum cleaner may be used to pick up loose dirt and debris.
*Low pressure air (not to exceed 25 psi) may be used to blow
away dirt. Inspect cooling air slots and openings on the generator.
These openings must be kept clean and unobstructed.
3.3.3 ENGINE MAINTENANCE
When working on the generator, always
disconnect spark plug wire from spark plug and keep wire
away from spark plug.
3.3.4 CHECKING OIL LEVEL
See the “before starting the generator” section for information on
checking the oil level. The oil level should be checked before
each use, or at least every eight hours of operation. Keep the oil
level maintained (figure 11).
A. Oil Drain
B. Oil Check & Fill
C. The highest oil level
Figure 11- Oil drain, check & fill
3.3.5 CHANGING THE OIL
Change the oil after the first ei
ght hours of operat
ion, then every
22
22