7.
At this time you should also decide whether or not everyone should logon or if you
want to allow a certain level of access without logon. As the system was supplied from
the factory no logon is required and everyone can have "Supervisor" Level of security.
8.
If you wish to change this, from the M415 Security Administration dialogue box select
"Advanced". A log on required check box and two default logon radio buttons will
appear. Selecting Logon Required will require everyone to have a logon and password
just to operate the system. If you do not want everyone to logon then select the level
(supervisor or operator) that they will have without logon.
5.12
PROJECT DATA RECORDING
The M-415 has the ability to record the following information and automatically print out this
information, along with the weld parameters used, at the end of each weld sequence:
1.
Weld Head Model Number used.
2.
Weld Head Serial Number used.
3.
Weld Name or ID number.
4.
Power Supply Serial Number used.
5.
Note
field
6.
Date and Time of Printout
7.
Date and Time of Weld Pass Sequence in WELD mode.
Items 1, 2, 3, 4 and 5 must be supplied by the user. To enter this information touch the control
panel icon (farthest right on tool bar) and then touch PROJECT DATA.
5.13 GENERAL
MAINTENANCE
NOTE
Calibration of the entire M-415 system is contained in the calibration section of the M-415
Maintenance Manual. Weld Head Travel and Wire Feed Calibration is contained in steps
5.10 and 5.11 of this section.
WARNING
Always disconnect the AC power cable from the line voltage before attempting any repairs to this
welding power supply.
1.
AIR FILTERS - The M-415 power supply has two (2) foam air filters behind a single screen in
the front of the power supply. Inspect these air filters regularly. To inspect, remove the
two captive screws at the top of the screen and tilt the screen forward to expose the filters.
The foam filters may be removed, washed in water and detergent, dried and reused or
replaced. Do not operate unit without filters in place.
2.
COOLANT - The coolant tank in the M-415 holds approximately 2.5 gallons. Check coolant
level periodically. Using different weld heads will remove coolant from the tank over a period
of time. Fill the tank per instructions of section 3.
3. Cleaning exterior and interior surfaces - Prolonged use in a dusty shop or outside
environments may cause the outside surfaces to accumulate a coating of dirt and dust. Do
not use shop air (usually too wet) to blow dust particles away from panels. Either wipe it off
with a damp cloth or use a vacuum cleaner with a soft brush . Where a vacuum brush
cannot reach, use clean, soft paint brush and then vacuum.
Document No. 740084
Revision N
40
Summary of Contents for 415
Page 1: ...MODEL 415 OPERATION MANUAL Document No 740084 Revision N ...
Page 19: ...Model 415 Operation Manual Document No 740084 Revision N 14 ...
Page 24: ...Model 415 Operation Manual Document No 740084 Revision N 19 ...
Page 25: ...Model 415 Operation Manual Document No 740084 Revision N 20 ...
Page 34: ...Model 415 Operation Manual Document No 740084 Revision N 29 ...