Model 415
Operation Manual
Document No. 740084
Revision N
9
3.
Motor Output Current Limit - User defined by weld head type in increments of
0.1 Amperes up to a maximum motor drive current limit of 4.0 Amperes.
4.
Motor Output Voltage Limit - 35 VDC
5.
Regulation Tolerance - +/- 2% of program value or +/- 1 inch, whichever is
greater. Based on maximum range being at least 100 IPM.
6.
Jogs - Motor servo provides for bi-directional (FEED and RETRACT) motor jogs. Jog
speeds
are
Adjustable.
2.6
TORCH OSCILLATION and CROSS-SEAM STEERING SERVO
1.
Range - User Defined by weld head type as to maximum programmable amplitude.
2.
Regulation - Closed loop position servo using +/- 5 VDC feedback voltage for
position information. Feedback device varies with weld head model. Intended for DC
permanent magnet type motors only.
3.
Motor Output Current Limit - User defined by weld head type in increments of
0.1 Amperes up to a maximum motor drive current limit of 4.0 Amperes.
4.
Motor Output Voltage Limit - 35 VDC
5.
Regulation Tolerance - +/- 1% of program value or 0.010 inches, whichever is greater.
Based solely on M-415 servo specification. Actual response speed and tolerance
performance can vary depending on the dynamic loads on the weld head. Consult the
weld head specification for each weld head tolerance.
6.
Jogs - No jogs are provided. Oscillator is continually seeking desired position. Position
is based on input (steering) commands from steering devices (on Pendant and Display).
2.7 TIMING
FUNCTIONS
1.
Purge Time Range (pre and post) -
000 to 1000 seconds. User can define minimum programmable time.
2.
Start Delay Time Range (Travel, Wire, AVC) -
00.0 to 100 seconds in increments of 0.1 seconds.
3.
Stop Delay Time Range (Travel, Wire, AVC) -
00 to 100 seconds.
4.
Upslope Time Range -
00.0 to 100 seconds. User can define minimum programmable time
5.
Downslope Time Range -
00 to 100 seconds. In increments of 1 second
6.
Weld Level Time Range (up to 99 levels) -
0000 to 10000 seconds.
7.
Pulse Timing Range (Primary/Background) -
0.00 to 100 seconds in increments of 0.01 seconds.
8.
Oscillator Timing Range (Dwells and Excursion) -
0.00 to 100 seconds in increments of 0.01 seconds.
9.
Primary WF pulse delay -
0.00 to 100 seconds in increments of 0.01 seconds.
10. Timing Resolution -
+/- 0.01 seconds (all timing functions)
2.8 ARC
STARTING
1.
Starting Methods - Touch or RF (radio frequency)
2.
Touch Start provides a smooth, consistent and tungsten inclusion free start with any weld
head that has an AVC. Touch and Retract speeds are user defined. User can set up for
single
start
attempt
or multiple start attempt.
3.
RF Starting provides a method of arc starting without the electrode touching the weld
surface. System is designed for best performance under the following conditions:
1.
Minimum
first
level
primary current - 5 Amperes (in Argon only)
2.
Gases - Argon, 95/5 Argon/Hydrogen, Helium or Helium/Argon Mixes.
3.
1 atmosphere pressure. Consult factory for operation in pressure chambers.
4.
Maximum arc gap - 0.156 inch (4 mm)
Summary of Contents for 415
Page 1: ...MODEL 415 OPERATION MANUAL Document No 740084 Revision N ...
Page 19: ...Model 415 Operation Manual Document No 740084 Revision N 14 ...
Page 24: ...Model 415 Operation Manual Document No 740084 Revision N 19 ...
Page 25: ...Model 415 Operation Manual Document No 740084 Revision N 20 ...
Page 34: ...Model 415 Operation Manual Document No 740084 Revision N 29 ...