Model 415
Operation Manual
Document No. 740084
Revision N
22
16.
BACKGROUND AVC
- Sets the Arc Voltage value in each level during the BACKGROUND
PULSE
time.
17.
AVC MODE
CONTINUOUS
- Regulates the Arc Voltage to the Primary AVC value during primary and
regulates the arc voltage to the Background AVC value during the background pulse.
SAMPLE ON THE PRIMARY
- Regulates the arc voltage servo to the Primary AVC value
during Primary pulse and turns the AVC servo (and motor) OFF during the Background.
SAMPLE ON THE BACKGROUND
- Regulates the arc voltage servo to the Background
AVC value during the Background pulse and turns the AVC servo (motor) OFF during the
Primary
pulse.
OFF
- Turns the AVC servo OFF and does not attempt to regulate the Arc Voltage.
18.
AVC RESPONSE
- Sets a value that determines how fast the AVC responds to errors in
the arc voltage value versus the programmed AVC value (primary and/or background).
19.
OSC IN DWELL TIME
- Sets the time that the Oscillator will be in the IN Dwell position
20.
OSC OUT DWELL TIME
- Sets the time that the Oscillator will be in the OUT Dwell position
21.
OSC EXCURSION TIME
- Sets the time that the Oscillator will take to move from the IN to
the OUT and the OUT to the IN.
22.
OSC AMPLITUDE
- Set the distance that the Oscillator moves from OUT to IN and IN to
OUT. User defines by weld head type the amplitude range.
23.
OSC MODE
-
ON - Allows the Oscillator to move at the Dwell/Excursion rate and Amplitude distance.
OFF - The OSC servo is only used for steering and does not move during sequence.
4.2.
SINGLE LEVEL FUNCTIONS and MODES
1.
PREPURGE
- The time that gas flows to the torch after Sequence Start and before arc start.
2.
START MODE
- Can be set to RF Start or Touch Start.
3.
TRAVEL MODE
- Determines which direction Clockwise or Counter Clockwise or OFF the
Travel Servo will drive the motor when the Travel Servo is enabled.
4.
UPSLOPE
- Sets the time that the Current and the Oscillator will take to rise to Level I
maximum values after arc start.
5.
TRAVEL START DELAY
- Sets the time from Arc Start until the Travel Servo is enabled.
6.
WIRE FEED START DELAY
- Sets the time from Arc Start until the Wire Feed Servo is
enabled.
7.
PRIMARY WIRE FEED PULSE DELAY
- Sets the amount of time the Wire Feed can be
delayed from changing to the Primary value from the Background value.
8.
AVC START DELAY
- Sets the time from Arc Start until the AVC Servo is enabled.
9.
DOWNSLOPE
- Sets the time that the Current and Oscillator will take to fall to minimum
programmable values before the arc goes out and Postpurge begins.
10.
TRAVEL STOP DELAY
- Sets the time the Travel Servo remains enabled after the
beginning of Downslope.
11.
WIRE FEED STOP DELAY
- Sets the time the Wire Feed Servo remains enabled after the
beginning of Downslope.
12.
AVC STOP DELAY
- Sets the time the AVC Servo remains enabled after the beginning of
Downslope.
13.
POSTPURGE
- Sets the time that gas continues to flow to the torch after the end of
Downslope and the arc has gone out.
4.3
MISCELLANEOUS NON-PROGRAMMABLE FUNCTIONS
1.
Return to Home
- System can be set up, by weld head type, to automatically at the end of
Post Purge, jog the Travel Servo and move the torch to the mount/dismount position or
starting position for next pass.
2.
Autowrap function
- System can be set up, by weld head type to allow the operator to
engage the autowrap function and wrap the cables prior to the start of weld sequence.
Summary of Contents for 415
Page 1: ...MODEL 415 OPERATION MANUAL Document No 740084 Revision N ...
Page 19: ...Model 415 Operation Manual Document No 740084 Revision N 14 ...
Page 24: ...Model 415 Operation Manual Document No 740084 Revision N 19 ...
Page 25: ...Model 415 Operation Manual Document No 740084 Revision N 20 ...
Page 34: ...Model 415 Operation Manual Document No 740084 Revision N 29 ...