Model 415
Operation Manual
Document No. 740084
Revision N
39
5.11 SYSTEM
SECURITY
1.
SECURITY
LEVELS
Authorization and access to the CREATE, MODIFY and DELETE functions should be
controlled. This control can be done via the password and login methods. There are 3 levels
of System access:
1.
Programmer
= Allows the user to set up or alter all user defined and controlled items
including Weld Head Templates, changing and adding passwords.
2.
Supervisor
= Allows the user to create and edit weld schedules, libraries and groups
and add other operators to the system. The supervisor level cannot alter Weld Head
Templates or add other supervisors or superuser’s to the system.
3.
Operator
= Is limited to only selecting and operating weld schedules and standard
system features. Operator level security prevents the user from making any permanent
changes to weld schedules or creating new weld schedules.
CAUTION
If you do not set up password and security levels then anyone can DELETE or alter Weld
Schedule
information.
2.
CHANGING/EDITING/ADDING LOGON and PASSWORDS
NOTE
The M-415 is shipped defaulted to the Supervisor level of security and logging in is not
required. It is recommended to create a new programmer Logon at once and delete AMI
superuser.
The following steps are for initial set up upon installation. Once the Superuser Logon
and password have been changed these steps will not work as written.
1.
From the AMI Logo Screen Main Menu go to the "File" and select "Log On".
A dialogue box titled "User Logon" will appear. Enter the Logon name of
ami
(lower
case) and the password of
superuser
(also lower case)
.
Select OK.
2.
A dialogue box with confirming date and access level will appear. Select OK.
The Main Logo screen will reappear and changes to Security can now be made.
3.
From the Main Menu go to "Edit" and select "Edit Users". A dialogue box titled
M415 Security Administration will appear and the list box will show only one user
named "Default Logon" with a logon of
ami
and a security level classification of
Programmer.
4.
Select Edit User, a dialogue box titled "M415 Security User Profile" will appear.
use this box to overwrite the default ami/superuser logon information with your
new superuser user name/logon/password. Be sure to keep the access
classification as Programmer. Select OK. A password confirmation screen
will appear, enter your new password again. Select OK.
5.
The Security List box will now show your new name/Logon and Classification.
6.
Once you have entered your new "programmer" level logon and password you can
now use the "Add User" function to add more users. The process is the same as
above.
Summary of Contents for 415
Page 1: ...MODEL 415 OPERATION MANUAL Document No 740084 Revision N ...
Page 19: ...Model 415 Operation Manual Document No 740084 Revision N 14 ...
Page 24: ...Model 415 Operation Manual Document No 740084 Revision N 19 ...
Page 25: ...Model 415 Operation Manual Document No 740084 Revision N 20 ...
Page 34: ...Model 415 Operation Manual Document No 740084 Revision N 29 ...