Remote Monitoring of Output Voltage and Current
TM-F2OP-C1XN-01
4-7
Remote Monitoring of Output Voltage and Current
Readback Signals
The J2 connector on the rear panel provides access to calibrated readback
signals for remote monitoring of the output voltage and current. Rear
panel switches SW1-5 and SW1-6 allow you to select either a 0-5 Vdc or
a 0-10 Vdc range for the output. The readback signal represents 0 to
100% of the power supply’s output.
for the required J2 connections and switch settings for
remote monitoring of readback signals with 0-5 Vdc or 0-10 Vdc outputs.
Use shielded pair wiring (20 to 24 AWG) and ground the shield to J10
sense connector terminal 1 (return sense) or to the chassis.
Note: Check the readback accuracy any time you reset switches SW1-5
and SW1-6. See Chapter 5.
Table 4-3
Settings for Remote Monitoring of Readback Signals
Readback Signal
J2 Connection
Signal (+)
J2 Connection
Return (–)
Switch SW1 Setting
Output Voltage
(0-5 Vdc)
J2-10
J2-9
SW1-5 OFF
(OPEN)
Output Voltage
(0-10 Vdc)
J2-10
J2-9
SW1-5 ON
(CLOSED)
Output Current
(0-5 Vdc)
J2-12
J2-11
SW1-6 OFF
(OPEN)
Output Current
(0-10 Vdc)
J2-12
J2-11
SW1-6 ON
(CLOSED)
Summary of Contents for Sorensen XFR 100-28
Page 3: ...This page intentionally left blank ii...
Page 5: ...This page intentionally left blank iv...
Page 7: ...This page intentionally left blank vi...
Page 13: ...xii...
Page 15: ...xiv...
Page 25: ...1 10...
Page 67: ...3 18...
Page 73: ...Remote Operation 4 6 TM F2OP C1XN 01 Figure 4 1 Connecting Programming Sources to J2 Connector...
Page 75: ...4 8...
Page 87: ...5 12...