![Ametek PCD 8 S Series Manual Download Page 36](http://html1.mh-extra.com/html/ametek/pcd-8-s-series/pcd-8-s-series_manual_2931379036.webp)
AMETEK CTS
PCD 8 s-series
Operating Manual
V 2.02
36 / 53
8.4.
ANSI coupling modes (only with second SCB)
For coupling modes required by ANSI standard, a second SCB needs to be added on the PCD 8 s.
Basic 1
L1+L2+L3+N - PE
Basic 2
L2 - L1
Basic 3
L3 - L2
Basic 4
L1 - L3
Supplemental 1
N - PE
Supplemental 2
L1 - PE
Supplemental 3
L2 - PE
Supplemental 4
L3 - PE
Diagnostic 1
L1+L2+L3 - N
Diagnostic 2
L1+L2+L3 - PE
Generator output Loop on SCB
Connection
from X1 to Y1
Decoupling network
PCD 8 s-3-690-1000-xxx
High
Low
N
L1
L2
L3
Basic 1
Y1
PE
No
Yes
Y3
Y2
X3
X2
Basic 2
X1
L1
No
No
X3
Basic 3
X1
L2
No
No
X2
Basic 4
Y1
L3
No
No
Y2
Supplemental 1
Y1
PE
No
No
Y3
Supplemental 2
Y1
PE
No
No
Y2
Supplemental 3
X1
PE
No
No
X3
Supplemental 4
X1
PE
No
No
X2
Diagnostic 1
Y1
N
No
Yes
Y2
X3
X2
Diagnostic 2
Y1
PE
No
Yes
Y2
X3
X2
NOTE ANSI A: Do not use the jumper Ji (ANSI A = 12 Ohm).
ANSI B: Use the jumper Ji (ANSI B = 2 Ohm). Use only jumpers as described in chapter 9!
Summary of Contents for PCD 8 S Series
Page 37: ...AMETEK CTS PCD 8 s series Operating Manual V 2 02 37 53 ...
Page 39: ...AMETEK CTS PCD 8 s series Operating Manual V 2 02 39 53 9 2 IEC coupling Line to Line 18 µF ...
Page 43: ...AMETEK CTS PCD 8 s series Operating Manual V 2 02 43 53 9 6 Optional ANSI coupling 1 5 Basic ...
Page 44: ...AMETEK CTS PCD 8 s series Operating Manual V 2 02 44 53 9 7 Optional ANSI coupling 2 5 Basic ...
Page 52: ......
Page 53: ...AMETEK CTS PCD 8 s series Manual of operation V 1 00 53 53 ...